Multidetector-row computed tomography angiography in abdominal aortic aneurysm treated with endovascular repair: evaluation of optimal timing of delayed phase imaging for the detection of low-flow endoleaks.

PURPOSE: To evaluate the optimal timing of delayed phase imaging for detecting low-flow endoleaks.

MATERIALS AND METHODS: Fifty-eight patients with unruptured abdominal aortic aneurysm treated with endovascular repair underwent 1- and 6-month follow-up multidetector row computed tomography (CT) performed during unenhanced, arterial, and delayed phase. At 6-month follow-up, delayed phase imaging, focused on stent graft, was performed with a delay of 60 (early delayed enhanced phase) and 300 seconds (late delayed enhanced phase) after intravenous injection of 120 mL of iodinated nonionic contrast medium (iomeprol 300 mgI/mL, Iomeron), at a flow rate of 3 mL/s via an antecubital vein, with a detector-row configuration of 4 x 1-mm, a 1.25-mm slice width, and a pitch of 6. Six-month follow-up CT images were independently evaluated by 2 readers during 2 different reading sessions: sets A (unenhanced, arterial, and early delayed phase images) and B (unenhanced, arterial, and late delayed phase images). Sensitivity and diagnostic accuracy of both reading sessions were compared. The standard of reference was represented by the combined evaluation of 1- and 6-month CT scans.

RESULTS: At standard of reference, 24 of 58 patients had an endoleak classified as type 1 in 2 cases, type 2 in 21 cases, and type 3 in the last 1 case. Seven of 21 type 2 endoleaks were classified as low-flow endoleaks. Set A reading session, including early delayed enhanced phase, allowed the detection of 19 of 24 endoleaks (5 false-negative cases represented by low-flow endoleaks), whereas all endoleaks were detected during set B reading session, including late delayed enhanced phase. Differences between sets A and B in terms of sensitivity and diagnostic accuracy were statistically significant (P < 0.05).

CONCLUSIONS: For optimal multidetector CT detection of low-flow endoleaks in patients who underwent endovascular repair, delayed phase should be acquired 300 seconds after injection of contrast medium.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app