A cohort evaluation of the pediatric ProSeal laryngeal mask airway in 100 children.
Paediatric Anaesthesia 2008 October
BACKGROUND: The ProSeal laryngeal mask airway (PLMA) has been available in pediatric sizes in the UK since 2007. Although several non-UK studies have evaluated PLMAs in children, there are little published data regarding their use in this country. Having decided to introduce the pediatric PLMA into our practice, we chose to prospectively audit the first 100 uses as part of our clinical governance.
METHODS: We studied children undergoing elective surgery who were considered suitable for a supraglottic airway. We recorded patient, surgical and insertion details, device performance data and complications. Patient management was not altered by inclusion in this audit.
RESULTS: Twenty size 1.5, 55 size 2.0, 15 size 2.5 and 10 size 3.0 PLMAs were inserted in 100 consecutive children [median age 2 years (range 2 months to 10 years) and median weight 15 kg (range 4.9-60 kg)]. The overall first attempt success rate was 93% (size 1.5, 100%; size 2.0, 100%; size 2.5, 87%; size 3.0, 90%) and overall successful insertion rate was 99%. Median leak pressure was 25 cmH(2)O. Outright failure was seen in one patient; complications were seen in another six patients (partial airway obstruction in five patients and mild laryngospasm in one patient), all of whom were transient and none of whom required intubation. No episodes of regurgitation were recorded.
CONCLUSIONS: Even without prior experience and using nonconventional insertion, pediatric PLMAs (including size 1.5) can be easily inserted and provide an effective airway.
METHODS: We studied children undergoing elective surgery who were considered suitable for a supraglottic airway. We recorded patient, surgical and insertion details, device performance data and complications. Patient management was not altered by inclusion in this audit.
RESULTS: Twenty size 1.5, 55 size 2.0, 15 size 2.5 and 10 size 3.0 PLMAs were inserted in 100 consecutive children [median age 2 years (range 2 months to 10 years) and median weight 15 kg (range 4.9-60 kg)]. The overall first attempt success rate was 93% (size 1.5, 100%; size 2.0, 100%; size 2.5, 87%; size 3.0, 90%) and overall successful insertion rate was 99%. Median leak pressure was 25 cmH(2)O. Outright failure was seen in one patient; complications were seen in another six patients (partial airway obstruction in five patients and mild laryngospasm in one patient), all of whom were transient and none of whom required intubation. No episodes of regurgitation were recorded.
CONCLUSIONS: Even without prior experience and using nonconventional insertion, pediatric PLMAs (including size 1.5) can be easily inserted and provide an effective airway.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app