Computed tomography model-based treatment of atrial fibrillation and atrial macro-re-entrant tachycardia.

AIMS: Accurate orientation within true three-dimensional (3D) anatomies is essential for the successful radiofrequency (RF) catheter ablation of atrial fibrillation (AF) and atrial macro-re-entrant tachycardia (MRT). In this prospective study, ablation of AF and MRT was performed exclusively using a pre-acquired and integrated computed tomography (CT) image for anatomical 3D orientation without electro-anatomic reconstruction of the left atrium (LA).

METHODS AND RESULTS: Fifty-four consecutive patients suffering from AF (n = 36) and/or MRT (n = 18) underwent RF catheter ablation. A 3D CT image was registered into the NavX-Ensite system without reconstruction of the atrial chamber anatomy. The quality of CT alignment was assessed and validated according to fluoroscopy information, electrogram characteristics, and tactile feedback at 31 pre-defined LA control points. The ablation of AF as well as mapping and ablation of MRT was performed within the 3D CT anatomy. In all patients, mapping and ablation could be performed without the reconstruction of the respective atrial chamber anatomy. The overall CT alignment was highly accurate with true surface contact in 90% (84%; 100%) of the control points. Complete isolation of all pulmonary vein (PV) funnels was achieved in 35 of 36 patients (97%) with AF. In patients with persistent AF (n = 11), additional isolation of the posterior LA (box lesion) and the placement of a mitral isthmus line were performed. The MRT mechanisms were as follows: around a PV ostium (n = 6), perimitral (n = 4), through LA roof (n = 5), septal (n = 2), and around left atrial appendage (n = 1). After a follow-up of 122 +/- 33 days, 22/25 (88%) patients with paroxysmal AF, 8/11 (73%) with persistent AF, and 16/18 (89%) with MRT remained free from arrhythmia recurrences.

CONCLUSION: For patients with AF and MRT, our study shows the feasibility of successful placement of complex linear ablation line concepts guided by an integrated 3D image anatomy alone rather than catheter-based virtual chamber surface reconstructions.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app