Numerical and experimental study of a novel phase contrast magnetic resonance (PC-MR) imaging technique: sparse interleaved referencing PC-MR imaging.

PURPOSE: To use numerical simulation and experimental approaches to introduce a novel phase contrast magnetic resonance (PC-MR) data processing technique termed Sparse Interleaved Referencing PC-MR, with potential to improve accuracy, temporal resolution, and signal-to-noise ratio (SNR) of PC-MR data.

MATERIALS AND METHODS: Computational fluid dynamics data were generated for a two-chamber orifice flow model simulating valvular regurgitation. The numerical results were validated and used to simulate conventional and Sparse Interleaved Referencing PC-MR data acquisitions. Common data sets were processed using conventional and Sparse Interleaved Referencing approaches and quantitative errors in velocity-time waveforms were measured and compared. In vitro phantom jet flow data and in vivo ascending aorta data were acquired and used to simulate Sparse Interleaved Referencing PC-MR.

RESULTS: The Sparse Interleaved Referencing PC-MR data showed significantly better representation of the velocity-time waveform in three areas: (i) lower root-mean-square errors (9.0 +/- 1.0% versus 24.0 +/- 0.2%; P < 0.005), (ii) simulation of conventionally processed data showed a pattern of peak velocity overestimation, which was experimentally demonstrated in in vitro data, whereas overestimation of peak velocity was dramatically attenuated using Sparse Interleaved Referencing (2.8 +/- 0.4% versus 16.9 +/- 6.4%, P < 0.005), and (iii) compared with the conventional scan, an average of 119.4 +/- 26.6% (P < 0.005) SNR was realized in in vitro and in vivo Sparse Interleaved Referencing PC-MR data.

CONCLUSION: Simulation and in vitro/in vivo results show that Sparse Interleaved Referencing PC-MR processed data in pulsatile and jet flow showed higher accuracy, better peak velocity representation, and improved SNR compared with the data processed using the conventional PC-MR method.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app