Journal Article
Meta-Analysis
Systematic Review
Add like
Add dislike
Add to saved papers

Electrocardiographic criteria for detecting acute myocardial infarction in patients with left bundle branch block: a meta-analysis.

STUDY OBJECTIVE: Numerous investigators have evaluated the ECG algorithm described by Sgarbossa et al to predict acute myocardial infarction in the presence of left bundle branch block and have arrived at divergent conclusions. To clarify the utility of the Sgarbossa ECG algorithm, we perform a systematic review and meta-analysis of these trials.

METHODS: A structured search was applied to MEDLINE and Scopus databases, beginning with the year that the algorithm was derived (1996). Two reviewers independently screened citations, assessed for method quality, and extracted data (individual study characteristics, screening performance, and interobserver agreement) with a standardized extraction tool. We assessed qualifying studies for heterogeneity and generated summary estimates for the sensitivity, specificity, and positive and negative likelihood ratios with fixed-effect models.

RESULTS: We identified 11 studies with 2,100 patients that met criteria for at least 1 component of the analysis. Ten studies with 1,614 patients reported a Sgarbossa ECG algorithm score of greater than or equal to 3. These yielded a summary sensitivity of 20% (95% confidence interval [CI] 18% to 23%), specificity of 98% (95% CI 97% to 99%), a positive likelihood ratio of 7.9 (95% CI 4.5 to 13.8), and a negative likelihood ratio of 0.8 (95% CI 0.8 to 0.9). The summary diagnostic odds ratio revealed homogeneity. Seven studies with 1,213 patients reported a Sgarbossa ECG algorithm score of greater than or equal to 2. These yielded sensitivities ranging from 20% to 79% and specificities ranging from 61% to 100%. Positive likelihood ratios ranged from 0.7 to 6.6 and negative likelihood ratios ranged from 0.2 to 1.1. The summary diagnostic odds ratio revealed heterogeneity. Intra- and interobserver agreement was substantial. Sensitivity analysis using the highest-quality studies yielded similar results.

CONCLUSION: A Sgarbossa ECG algorithm score of greater than or equal to 3, representing greater than or equal to 1 mm of concordant ST elevation or greater than or equal to 1 mm ST depression in leads V1 to V3, is useful for diagnosing acute myocardial infarction in patients who present with left bundle branch block on ECG. The scoring system demonstrates good to excellent overall interobserver variability. A score of 2, representing 5 mm or more of discordant ST deviation, demonstrated ineffective positive likelihood ratios. A Sgarbossa ECG algorithm score of 0 is not useful in excluding acute myocardial infarction.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app