Acute effects of MK63 stun device discharges in miniature swine.

Military Medicine 2008 Februrary
OBJECTIVE: Electromuscular incapacitation (EMI) devices are being used and evaluated by both military and law enforcement agencies. Although the gross muscular response is obvious, physiological responses to these devices are poorly understood. We hypothesized that the intense, repetitive, muscle contractions evoked by EMI devices would cause dose-dependent metabolic acidosis, accompanied by neuromuscular or cardiac injury.

METHODS: Using an approved protocol, 26 Yucatan mini-pigs (22 experimental animals and 4 control animals) were anesthetized with ketamine and xylazine. Experimental animals were exposed to MK63 (Aegis Industries, Bellevue, Idaho) discharges over the left anterior hind limb for 10, 20, 40, or 80 seconds. Electrocardiograms, electromyograms, troponin I levels, blood gas values, and electrolyte levels were recorded before and 5, 15, 30, and 60 minutes and 24, 48, and 72 hours after discharge. Skin, muscle, and nerve biopsies were taken from the shocked and contralateral sides.

RESULTS: Core body temperature significantly decreased (1.0-1.5 degrees C) in all shocked animals but not in sham-treated control animals. No cardiac dysrhythmias or deaths were seen, and heart rate was unaffected. No clinically significant changes were seen in troponin I, myoglobin, or creatine kinase-MB levels. Central venous blood pH decreased, whereas carbon dioxide pressure and lactate levels increased for 60 minutes after discharge. All values returned to normal by 24 hours after discharge, and no significant histological or electromyographic changes were found.

CONCLUSIONS: Changes in blood chemistry were observed but were of little clinical significance, and no neuromuscular damage was detected. Therefore, within the limitations of this model, it appears that EMI can safely be achieved by using this device, even for lengthy periods, without causing significant injury.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app