We have located links that may give you full text access.
Evaluation Study
Journal Article
Meta-Analysis
Review
The diagnostic accuracy of CT and MRI in the staging of pelvic lymph nodes in patients with prostate cancer: a meta-analysis.
Clinical Radiology 2008 April
AIM: To compare the diagnostic accuracy of computed tomography (CT) and magnetic resonance imaging (MRI) in the diagnosis of lymph node metastases in prostate cancer.
METHODS: After a comprehensive literature search, studies were included that allowed construction of contingency tables for detection of lymph node metastases using CT or MRI. In addition, a summary receiver-operating characteristic (ROC) analysis was performed.
RESULTS: A total of 24 studies were included. For CT, pooled sensitivity was 0.42 (0.26-0.56 95% CI) and pooled specificity was 0.82 (0.8-0.83 95% CI). For MRI, the pooled sensitivity was 0.39 (0.22-0.56 95% CI) and pooled specificity was 0.82 (0.79-0.83 95% CI). The differences in performance of CT and MRI were not statistically significant.
CONCLUSION: CT and MRI demonstrate an equally poor performance in the detection of lymph node metastases from prostate cancer. Reliance on either CT or MRI will misrepresent the patient's true status regarding nodal metastases, and thus misdirect the therapeutic strategies offered to the patient.
METHODS: After a comprehensive literature search, studies were included that allowed construction of contingency tables for detection of lymph node metastases using CT or MRI. In addition, a summary receiver-operating characteristic (ROC) analysis was performed.
RESULTS: A total of 24 studies were included. For CT, pooled sensitivity was 0.42 (0.26-0.56 95% CI) and pooled specificity was 0.82 (0.8-0.83 95% CI). For MRI, the pooled sensitivity was 0.39 (0.22-0.56 95% CI) and pooled specificity was 0.82 (0.79-0.83 95% CI). The differences in performance of CT and MRI were not statistically significant.
CONCLUSION: CT and MRI demonstrate an equally poor performance in the detection of lymph node metastases from prostate cancer. Reliance on either CT or MRI will misrepresent the patient's true status regarding nodal metastases, and thus misdirect the therapeutic strategies offered to the patient.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app