Journal Article
Research Support, Non-U.S. Gov't
Research Support, U.S. Gov't, P.H.S.
Add like
Add dislike
Add to saved papers

The use of mechanical circulatory support as a bridge to transplantation in pediatric patients: an analysis of the United Network for Organ Sharing database.

OBJECTIVES: The use of mechanical circulatory support to bridge pediatric patients to cardiac transplantation presents unique challenges because of the difficult anatomy and physiology in these patients.

METHODS: The United Network for Organ Sharing provided deidentifed patient-level data. The study population included 2532 transplantations performed on patients less than 19 years old in status 1/1A/1B between 1995 and 2005. Mechanical circulatory support was used in 431 patients: 241 (9.5%) received ventricular assist devices, 171 (6.8%) underwent extracorporeal membrane oxygenation, and 19 (0.8%) received intra-aortic balloon pumps.

RESULTS: Patients supported on ventricular assist devices had similar levels of hospitalization and intensive care use and less need for inotropic support (P < .0002) than had those not needing support. Five- and 10-year posttransplantation survival was better in patients receiving ventricular assist devices and patients not receiving mechanical circulatory support than in patients receiving extracorporeal membrane oxygenation or intra-aortic balloon pumping (P < .0001). Among mechanically supported patients, patients with a body surface area of less than 0.30 (odds ratio, 1.70; 95% confidence interval, 1.18-2.43) and those requiring extracorporeal membrane oxygenation (odds ratio, 1.65; 95% confidence interval, 1.15-2.35) or intra-aortic balloon pumping (odds ratio, 1.91; 95% confidence interval, 1.02-3.56) had higher long-term mortality. The use of a ventricular assist device at transplantation did not predict higher long-term, posttransplantation mortality.

CONCLUSIONS: Pediatric patients requiring a pretransplantation ventricular assist device have long-term survival similar to that of patients not receiving mechanical circulatory support. Early survival among patients undergoing extracorporeal membrane oxygenation and infants is poor, reinforcing the need for improvements in device design and physiologic management of infants and neonates.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app