COMPARATIVE STUDY
JOURNAL ARTICLE

Persistently better treatment planning results of intensity-modulated (IMRT) over conformal radiotherapy (3D-CRT) in prostate cancer patients with significant variation of clinical target volume and/or organs-at-risk

Pascal Fenoglietto, Benoit Laliberte, Ali Allaw, Norbert Ailleres, Katia Idri, Meng Huor Hay, Carmen Llacer Moscardo, Sophie Gourgou, Jean-Bernard Dubois, David Azria
Radiotherapy and Oncology 2008, 88 (1): 77-87
18215434

PURPOSE: To compare the dose coverage of planning and clinical target volume (PTV, CTV), and organs-at-risk (OAR) between intensity-modulated (3D-IMRT) and conventional conformal radiotherapy (3D-CRT) before and after internal organ variation in prostate cancer.

METHODS AND MATERIALS: We selected 10 patients with clinically significant interfraction volume changes. Patients were treated with 3D-IMRT to 80 Gy (minimum PTV dose of 76 Gy, excluding rectum). Fictitious, equivalent 3D-CRT plans (80 Gy at isocenter, with 95% isodose (76 Gy) coverage of PTV, with rectal blocking above 76 Gy) were generated using the same planning CT data set ("CT planning"). The plans were then also applied to a verification CT scan ("CT verify") obtained at a different moment. PTV, CTV, and OAR dose coverage were compared using non-parametric tests statistics for V95, V90 (% of the volume receiving 95 or 90% of the dose) and D50 (dose to 50% of the volume).

RESULTS: Mean V95 of the PTV for "CT planning" was 94.3% (range, 88-99) vs 89.1% (range, 84-94.5) for 3D-IMRT and 3D-CRT (p=0.005), respectively. Mean V95 of the CTV for "CT verify" was 97% for both 3D-IMRT and 3D-CRT. Mean D50 of the rectum for "CT planning" was 26.8 Gy (range, 22-35) vs 43.5 Gy (range, 33.5-50.5) for 3D-IMRT and 3D-CRT (p=0.0002), respectively. For "CT verify", this D50 was 31.1 Gy (range, 16.5-44) vs 44.2 Gy (range, 34-55) for 3D-IMRT and 3D-CRT (p=0.006), respectively. V95 of the rectum was 0% for both plans for "CT planning", and 2.3% (3D-IMRT) vs 2.1% (3D-CRT) for "CT verify" (p=non-sig.).

CONCLUSION: Dose coverage of the PTV and OAR was better with 3D-IMRT for each patient and remained so after internal volume changes.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
18215434
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"