COMPARATIVE STUDY
JOURNAL ARTICLE
VALIDATION STUDIES
The reliability of knee joint position testing using electrogoniometry.
BACKGROUND: The current investigation examined the inter- and intra-tester reliability of knee joint angle measurements using a flexible Penny and Giles Biometric electrogoniometer. The clinical utility of electrogoniometry was also addressed.
METHODS: The first study examined the inter- and intra-tester reliability of measurements of knee joint angles in supine, sitting and standing in 35 healthy adults. The second study evaluated inter-tester and intra-tester reliability of knee joint angle measurements in standing and after walking 10 metres in 20 healthy adults, using an enhanced measurement protocol with a more detailed electrogoniometer attachment procedure. Both inter-tester reliability studies involved two testers.
RESULTS: In the first study, inter-tester reliability (ICC[2,10]) ranged from 0.58-0.71 in supine, 0.68-0.79 in sitting and 0.57-0.80 in standing. The standard error of measurement between testers was less than 3.55 degrees and the limits of agreement ranged from -12.51 degrees to 12.21 degrees . Reliability coefficients for intra-tester reliability (ICC[3,10]) ranged from 0.75-0.76 in supine, 0.86-0.87 in sitting and 0.87-0.88 in standing. The standard error of measurement for repeated measures by the same tester was less than 1.7 degrees and the limits of agreement ranged from -8.13 degrees to 7.90 degrees . The second study showed that using a more detailed electrogoniometer attachment protocol reduced the error of measurement between testers to 0.5 degrees .
CONCLUSION: Using a standardised protocol, reliable measures of knee joint angles can be gained in standing, supine and sitting by using a flexible goniometer.
METHODS: The first study examined the inter- and intra-tester reliability of measurements of knee joint angles in supine, sitting and standing in 35 healthy adults. The second study evaluated inter-tester and intra-tester reliability of knee joint angle measurements in standing and after walking 10 metres in 20 healthy adults, using an enhanced measurement protocol with a more detailed electrogoniometer attachment procedure. Both inter-tester reliability studies involved two testers.
RESULTS: In the first study, inter-tester reliability (ICC[2,10]) ranged from 0.58-0.71 in supine, 0.68-0.79 in sitting and 0.57-0.80 in standing. The standard error of measurement between testers was less than 3.55 degrees and the limits of agreement ranged from -12.51 degrees to 12.21 degrees . Reliability coefficients for intra-tester reliability (ICC[3,10]) ranged from 0.75-0.76 in supine, 0.86-0.87 in sitting and 0.87-0.88 in standing. The standard error of measurement for repeated measures by the same tester was less than 1.7 degrees and the limits of agreement ranged from -8.13 degrees to 7.90 degrees . The second study showed that using a more detailed electrogoniometer attachment protocol reduced the error of measurement between testers to 0.5 degrees .
CONCLUSION: Using a standardised protocol, reliable measures of knee joint angles can be gained in standing, supine and sitting by using a flexible goniometer.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app