We have located links that may give you full text access.
Reconstruction of the medial patellofemoral ligament with gracilis tendon autograft in transverse patellar drill holes.
Arthroscopy 2008 January
PURPOSE: We present clinical results in a case series of 44 patients with medial patellofemoral ligament (MPFL) reconstruction with 12 to 32 months' follow-up.
METHODS: Reconstruction was performed via gracilis tendon autograft looped through 2 transverse 4.5-mm drill holes in the patella and fixed at the natural MPFL insertion site on the medial femoral condyle with an interference screw. At follow-up, Kujala scores, Knee Injury and Osteoarthritis Outcome Scores, objective knee function, complications, and reoperations were assessed.
RESULTS: Only 1 patella redislocation was observed. Subluxation occurred in 3 patients, whereas 4 patients had chronic pain at follow-up, all of whom had cartilage injury at surgery. The Kujala knee function score improved overall from 46 points (range, 12 to 67 points) to 84 points (range, 62 to 100 points) at follow-up.
CONCLUSIONS: MPFL reconstruction with double transverse patella drill holes and a gracilis tendon graft provides good postoperative patellar stability. Postoperative pain seems to be related to the degree of patellofemoral injury found at surgery.
LEVEL OF EVIDENCE: Level IV, therapeutic case series.
METHODS: Reconstruction was performed via gracilis tendon autograft looped through 2 transverse 4.5-mm drill holes in the patella and fixed at the natural MPFL insertion site on the medial femoral condyle with an interference screw. At follow-up, Kujala scores, Knee Injury and Osteoarthritis Outcome Scores, objective knee function, complications, and reoperations were assessed.
RESULTS: Only 1 patella redislocation was observed. Subluxation occurred in 3 patients, whereas 4 patients had chronic pain at follow-up, all of whom had cartilage injury at surgery. The Kujala knee function score improved overall from 46 points (range, 12 to 67 points) to 84 points (range, 62 to 100 points) at follow-up.
CONCLUSIONS: MPFL reconstruction with double transverse patella drill holes and a gracilis tendon graft provides good postoperative patellar stability. Postoperative pain seems to be related to the degree of patellofemoral injury found at surgery.
LEVEL OF EVIDENCE: Level IV, therapeutic case series.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
The Effect of Albumin Administration in Critically Ill Patients: A Retrospective Single-Center Analysis.Critical Care Medicine 2024 Februrary 8
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app