A preliminary evaluation of the mean arterial pressure as measured by cuff oscillometry.
American Journal of Hypertension 2008 Februrary
BACKGROUND: The brachial artery (BA) mean blood pressure (MBP) is now readily available using the oscillometric technique. In contrast to the auscultatory method where MBP is calculated from the systolic (SBP) and diastolic blood pressure (DBP), oscillometric MBP is measured separately from either SBP or DBP. Because the peripheral MBP is free of amplification, it is nearly the same throughout the entire arterial tree and could represent the corresponding aortic pressure. The oscillometric brachial MBP could therefore serve as a surrogate for aortic MBP and might be a valuable non-invasive risk predictor.
METHODS: This study compares the oscillometric BA pressures with simultaneously and directly recorded aortic pressures in 100 patients.
RESULTS: These results show that, over a wide range of cuff pressures, the oscillometric MBP, whether alone or with age in multiple regression, predicts aortic pressure better than the SBP or DBP do, with a better correlation coefficient (r = +0.91), low aortic-cuff MBP difference (-0.79 mm Hg) and the lowest s.d. of the individual differences (+7.2 mm Hg).
CONCLUSIONS: These results are preliminary and need to be confirmed by larger studies. If confirmed, the predicted aortic pressures should be calculated and displayed by the oscillometric BP devices, the goal being to develop better non-invasive cardiovascular (CV) risk predictors.
METHODS: This study compares the oscillometric BA pressures with simultaneously and directly recorded aortic pressures in 100 patients.
RESULTS: These results show that, over a wide range of cuff pressures, the oscillometric MBP, whether alone or with age in multiple regression, predicts aortic pressure better than the SBP or DBP do, with a better correlation coefficient (r = +0.91), low aortic-cuff MBP difference (-0.79 mm Hg) and the lowest s.d. of the individual differences (+7.2 mm Hg).
CONCLUSIONS: These results are preliminary and need to be confirmed by larger studies. If confirmed, the predicted aortic pressures should be calculated and displayed by the oscillometric BP devices, the goal being to develop better non-invasive cardiovascular (CV) risk predictors.
Full text links
Related Resources
Trending Papers
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Anti-Arrhythmic Effects of Heart Failure Guideline-Directed Medical Therapy and Their Role in the Prevention of Sudden Cardiac Death: From Beta-Blockers to Sodium-Glucose Cotransporter 2 Inhibitors and Beyond.Journal of Clinical Medicine 2024 Februrary 27
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app