We have located links that may give you full text access.
JOURNAL ARTICLE
RANDOMIZED CONTROLLED TRIAL
Volumetric bladder ultrasound performed by trained nurses increases catheterization success in pediatric patients.
American Journal of Emergency Medicine 2008 January
OBJECTIVE: The objective of the study was to determine whether the use of volumetric ultrasound by trained pediatric emergency department (ED) nurses improves first-attempt urine collection success rates.
METHODS: This randomized controlled trial was conducted in children aged < or = 36 months requiring diagnostic urine samples. Children were randomized to either the conventional (nonimaged) or the ultrasound arm. Demographics, number of catheterizations required for success, postponements, and collection times were recorded.
RESULTS: Forty-five children were assigned to the conventional and 48 to the ultrasound arm (n = 93). First-attempt success rates were higher in the ultrasound arm: 67% (conventional) vs 92% (ultrasound) (P = .003). Both urinalysis and culture were less likely to be completed on conventional group specimens (91% vs 100%; P = .04). However, mean conventional group urine collection time was less than the ultrasound group's collection time (12 vs 28 minutes; P < .001).
CONCLUSIONS: Although there is a time delay, urine collection in the ultrasound arm generated a significant improvement over conventional catheterization in obtaining an adequate urine sample.
METHODS: This randomized controlled trial was conducted in children aged < or = 36 months requiring diagnostic urine samples. Children were randomized to either the conventional (nonimaged) or the ultrasound arm. Demographics, number of catheterizations required for success, postponements, and collection times were recorded.
RESULTS: Forty-five children were assigned to the conventional and 48 to the ultrasound arm (n = 93). First-attempt success rates were higher in the ultrasound arm: 67% (conventional) vs 92% (ultrasound) (P = .003). Both urinalysis and culture were less likely to be completed on conventional group specimens (91% vs 100%; P = .04). However, mean conventional group urine collection time was less than the ultrasound group's collection time (12 vs 28 minutes; P < .001).
CONCLUSIONS: Although there is a time delay, urine collection in the ultrasound arm generated a significant improvement over conventional catheterization in obtaining an adequate urine sample.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university