Validation of limited sampling strategy for the estimation of mycophenolic acid exposure in Chinese adult liver transplant recipients.

Liver Transplantation 2007 December
Mycophenolate mofetil (MMF) is indicated as immunosuppressive therapy in liver transplantation. The abbreviated models for the estimation of mycophenolic acid (MPA) area under the concentration-time curve (AUC) have been established by limited sampling strategies (LSSs) in adult liver transplant recipients. In the current study, the performance of the abbreviated models to predict MPA exposure was validated in an independent group of patients. A total of 30 MPA pharmacokinetic profiles from 30 liver transplant recipients receiving MMF in combination with tacrolimus were used to compare 8 models' performance with a full 10 time-point MPA-AUC. Linear regression analysis and Bland-Altman analysis were used to compare the estimated MPA-AUC0-12h from each model against the measured MPA-AUC0-12h. A wide range of agreement was shown when estimated MPA-AUC0-12h was compared with measured MPA-AUC0-12h, and the range of coefficient of determination (r2) was from 0.479 to 0.936. The model based on MPA pharmacokinetic parameters C1h, C2h, C6h, and C8h had the best ability to predict measured MPA-AUC0-12h, with the best coefficient of determination (r2=0.936), the excellent prediction bias (2.18%), the best prediction precision (5.11%), and the best prediction variation (2SD=+/-7.88 mg.h/L). However, the model based on MPA pharmacokinetic sampling time points C1h, C2h, and C4h was more suitable when concerned with clinical convenience, which had shorter sampling interval, an excellent coefficient of determination (r2=0.795), an excellent prediction bias (3.48%), an acceptable prediction precision (14.37%), and a good prediction variation (2SD=+/-13.23 mg.h/L). Measured MPA-AUC0-12h could be best predicted by using MPA pharmacokinetic parameters C1h, C2h, C6h, and C8h. The model based on MPA pharmacokinetic parameters C1h, C2h, and C4h was more feasible in clinical application.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app