Segmental polymethylmethacrylate-augmented pedicle screw fixation in patients with bone softening caused by osteoporosis and metastatic tumor involvement: a clinical evaluation.

Neurosurgery 2007 September
OBJECTIVE: Instrumentation of the osteoporotic spine may result in bone failure because of pedicle screw loosening and pullout. A clinical evaluation of a novel fenestrated bone tap used in pedicle screw augmentation was performed to determine the performance and safety of this technique.

METHODS: Over a 2.5-year period, the clinical and radiographic results of 119 consecutive patients who underwent instrumented arthrodesis were reviewed. Of these patients, 23 had bone softening secondary to osteoporosis and/or metastatic spinal tumor involvement. These patients underwent surgical decompression and spinal instrumentation.

RESULTS: Six patients (26%) had metastatic spine disease (squamous cell lung carcinoma, renal cell carcinoma, bladder carcinoma, breast, prostate, and uterine adenocarcinoma); five patients (22%) had a degenerative spondylolisthesis; and 12 patients (52%) had burst fractures, eight as a result of benign causes and four as a result of metastatic disease. Four (17%) patients underwent revision surgery of previous pedicle screw failure resulting from bone softening and pseudarthrosis. A total of 98 levels were fused using 158 polymethylmethacrylate-augmented screws. None of the patients experienced operative death, myocardial infarction, hypoxemia, intraoperative hypotension, radiculopathy, or myelopathy. Asymptomatic anterior cement extravasation was observed in nine patients (39%). There was one asymptomatic polymethylmethacrylate pulmonary embolus and one wound infection. There was no significant relationship between cement extravasation and the quantity used, levels augmented, or location (P > 0.05). There were no construct failures.

CONCLUSION: Polymethylmethacrylate-augmented pedicle screw fixation reduces the likelihood of pedicle screw loosening and pullout in patients with osteoporosis requiring instrumented arthrodesis.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Group 7SearchHeart failure treatmentPapersTopicsCollectionsEffects of Sodium-Glucose Cotransporter 2 Inhibitors for the Treatment of Patients With Heart Failure Importance: Only 1 class of glucose-lowering agents-sodium-glucose cotransporter 2 (SGLT2) inhibitors-has been reported to decrease the risk of cardiovascular events primarily by reducingSeptember 1, 2017: JAMA CardiologyAssociations of albuminuria in patients with chronic heart failure: findings in the ALiskiren Observation of heart Failure Treatment study.CONCLUSIONS: Increased UACR is common in patients with heart failure, including non-diabetics. Urinary albumin creatininineJul, 2011: European Journal of Heart FailureRandomized Controlled TrialEffects of Liraglutide on Clinical Stability Among Patients With Advanced Heart Failure and Reduced Ejection Fraction: A Randomized Clinical Trial.Review

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app