Patient-ventilator synchrony during pressure-targeted versus flow-targeted small tidal volume assisted ventilation.
Journal of Critical Care 2007 September
PURPOSE: Low tidal volume (V(T)) delivered by flow-targeted breaths reduces ventilator-induced lung injury but may increase patient breathing effort because of limited flow. We hypothesized that a variable-flow, pressure-targeted breath would improve breathing effort versus a fixed flow-targeted breath.
MATERIALS AND METHODS: We compared pressure assist-control ventilation and volume assist-control ventilation (VACV) in 12 patients with acute respiratory failure receiving 6 to 8 mL/kg V(T). Backup frequency, V(T), inspiratory time, applied positive end-expiratory pressure and fraction of inspired oxygen were held constant. Patient breathing effort was assessed by airway pressure (Paw) drop below baseline 0.1 second after the breath initiation (P(0.1)), the maximal Paw drop during the triggering phase (Ptr), the magnitude of ventilator work during flow delivery, and the presence of an active expiratory effort during cycling and air trapping judged by the magnitude of residual flow at end-expiration.
RESULTS: Compared with VACV, pressure assist-control ventilation decreased P(0.1), Ptr (by 25% and 16%, respectively), and evidence for trapped gas but not ventilator work during flow delivery or cycle dys-synchrony. Peak inspiratory flow was comparable between the 2 modes.
CONCLUSIONS: In patients receiving small V(T) VACV with increased breathing effort, variable-flow, pressure-targeted ventilation may provide more comfort by decreasing respiratory drive during the triggering phase.
MATERIALS AND METHODS: We compared pressure assist-control ventilation and volume assist-control ventilation (VACV) in 12 patients with acute respiratory failure receiving 6 to 8 mL/kg V(T). Backup frequency, V(T), inspiratory time, applied positive end-expiratory pressure and fraction of inspired oxygen were held constant. Patient breathing effort was assessed by airway pressure (Paw) drop below baseline 0.1 second after the breath initiation (P(0.1)), the maximal Paw drop during the triggering phase (Ptr), the magnitude of ventilator work during flow delivery, and the presence of an active expiratory effort during cycling and air trapping judged by the magnitude of residual flow at end-expiration.
RESULTS: Compared with VACV, pressure assist-control ventilation decreased P(0.1), Ptr (by 25% and 16%, respectively), and evidence for trapped gas but not ventilator work during flow delivery or cycle dys-synchrony. Peak inspiratory flow was comparable between the 2 modes.
CONCLUSIONS: In patients receiving small V(T) VACV with increased breathing effort, variable-flow, pressure-targeted ventilation may provide more comfort by decreasing respiratory drive during the triggering phase.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app