We have located links that may give you full text access.
COMPARATIVE STUDY
JOURNAL ARTICLE
RESEARCH SUPPORT, N.I.H., EXTRAMURAL
RESEARCH SUPPORT, NON-U.S. GOV'T
Optic disk and nerve fiber layer imaging to detect glaucoma.
American Journal of Ophthalmology 2007 November
PURPOSE: To compare optic disk and retinal nerve fiber layer (RNFL) imaging methods to discriminate eyes with early glaucoma from normal eyes.
DESIGN: Retrospective, cross-sectional study.
METHODS: In a tertiary care academic glaucoma center, 92 eyes of 92 subjects (46 with early perimetric open-angle glaucoma and 46 controls) were studied. Diagnostic performance of optical coherence tomography (StratusOCT; Carl Zeiss Meditec, Dublin, California, USA), scanning laser polarimetry (GDx VCC; Laser Diagnostic Technologies, San Diego, California, USA), confocal laser ophthalmoscopy (Heidelberg Retinal Tomograph [HRT] III; Heidelberg Engineering GmbH, Heidelberg, Germany), and qualitative assessment of stereoscopic optic disk photographs were compared. Outcome measures were areas under receiver operator characteristic curves (AUCs) and sensitivities at fixed specificities. Classification and regression tree (CART) analysis was used to evaluate combinations of quantitative parameters.
RESULTS: The average (+/- standard deviation) visual field mean deviation for glaucomatous eyes was -4.0 +/- 2.5 dB (decibels). Parameters with largest AUCs (+/- standard error) were: average RNFL thickness for StratusOCT (0.96 +/- 0.02), nerve fiber indicator for GDx VCC (0.92 +/- 0.03), Frederick S. Mikelberg (FSM) discriminant function for HRT III (0.91 +/- 0.03), and 0.97 +/- 0.02 for disk photograph evaluation. At 95% specificity, sensitivity of disk photograph evaluation (90%) was greater than GDx VCC (P = .05) and HRT III (P = .002) results, but not significantly different than those of StratusOCT (P > .05). The combination of StratusOCT average RNFL thickness and HRT III cup-to-disk area with CART produced a sensitivity of 91% and specificity of 96%.
CONCLUSIONS: StratusOCT, GDx VCC, and HRT III performed as well as, but not better than, qualitative evaluation of optic disk stereophotographs for detection of early perimetric glaucoma. The combination of StratusOCT average RNFL thickness and HRT III cup-to-disk area ratio provided a high diagnostic precision.
DESIGN: Retrospective, cross-sectional study.
METHODS: In a tertiary care academic glaucoma center, 92 eyes of 92 subjects (46 with early perimetric open-angle glaucoma and 46 controls) were studied. Diagnostic performance of optical coherence tomography (StratusOCT; Carl Zeiss Meditec, Dublin, California, USA), scanning laser polarimetry (GDx VCC; Laser Diagnostic Technologies, San Diego, California, USA), confocal laser ophthalmoscopy (Heidelberg Retinal Tomograph [HRT] III; Heidelberg Engineering GmbH, Heidelberg, Germany), and qualitative assessment of stereoscopic optic disk photographs were compared. Outcome measures were areas under receiver operator characteristic curves (AUCs) and sensitivities at fixed specificities. Classification and regression tree (CART) analysis was used to evaluate combinations of quantitative parameters.
RESULTS: The average (+/- standard deviation) visual field mean deviation for glaucomatous eyes was -4.0 +/- 2.5 dB (decibels). Parameters with largest AUCs (+/- standard error) were: average RNFL thickness for StratusOCT (0.96 +/- 0.02), nerve fiber indicator for GDx VCC (0.92 +/- 0.03), Frederick S. Mikelberg (FSM) discriminant function for HRT III (0.91 +/- 0.03), and 0.97 +/- 0.02 for disk photograph evaluation. At 95% specificity, sensitivity of disk photograph evaluation (90%) was greater than GDx VCC (P = .05) and HRT III (P = .002) results, but not significantly different than those of StratusOCT (P > .05). The combination of StratusOCT average RNFL thickness and HRT III cup-to-disk area with CART produced a sensitivity of 91% and specificity of 96%.
CONCLUSIONS: StratusOCT, GDx VCC, and HRT III performed as well as, but not better than, qualitative evaluation of optic disk stereophotographs for detection of early perimetric glaucoma. The combination of StratusOCT average RNFL thickness and HRT III cup-to-disk area ratio provided a high diagnostic precision.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app