EVALUATION STUDIES
JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Utilization of calculated low density lipoprotein cholesterol and measured low density lipoprotein cholesterol in Siriraj Hospital.

A study to determine the utilization of calculated low density lipoprotein (c-LDL) cholesterol and measured low density lipoprotein (m-LDL) cholesterol was conducted. The test results of total cholesterol, triglyceride, HDL-cholesterol and m-LDL-cholesterol from the same individuals aged > or = 18 years who had the tests done at the Department of Clinical Pathology, Faculty of Medicine Siriraj Hospital during January to December 2004 were retrieved. The c-LDL-cholesterol level was computed using Friedewald formula. There were two data sets i.e. the m-LDL-cholesterol cut-off level derivation data set (784 subjects) and the m-LDL-cholesterol cut-off level validation data set (800 subjects). The study results revealed: 1) 2.6% of the subjects had blood triglyceride > 400 mg/dl hence c-LDL-cholesterol could not be computed, 2) the correlation between c-LDL-cholesterol levels and m-LDL-cholesterol levels from both data sets was very good (r > 0. 95, p < 0. 001), 3) the m-LDL-cholesterol levels were usually higher than c-LDL-cholesterol levels, 4) the m-LDL-cholesterol cut-off level derivation data set showed that m-LDL-cholesterol < 87, > 143, > 188, > 233 and > 254 mg/dl were highly correlated with c-LDL-cholesterol < 100, > or = 100, > or = 130, > or = 160 and > or = 190 mg/dl respectively, 5) an application of m-LDL-cholesterol cut-off levels derived from the m-LDL-cholesterol cut-off level derivation data set to the m-LDL-cholesterol cut-off level validation data set showed that m-LDL-cholesterol < 87, > 143, > 188, > 233 and > 254 mg/dl had accuracy in predicting c-LDL-cholesterol < 100, > or = 100, > or = 130, > or = 160 and > or = 190 mg/dl of 100%, 99. 7%, 100%, 100% and 100% respectively, 6) the use of m-LDL-cholesterol levels as a guide for initiating lipid-lowering agents based on cut-off values of c-LDL-cholesterol levels led to an overuse of lipid-lowering agents in 3.6% to 42.9% of the patients and 7) Nomogram for transforming m-LDL-cholesterol to c-LDL-cholesterol was developed as well as a formula for transforming m-LDL-cholesterol to c-LDL-cholesterol (c-LDL-cholesterol = 0.89 x m-LDL-cholesterol). Therefore, m-LDL-cholesterol assay has a very limited use in managing individuals with suspected or known dyslipidemia. The use of m-LDL-cholesterol level as a guide for management of abnormal LDL-cholesterol conditions leads to an overuse of lipid lowering medications and an enormous expense of m-LDL-cholesterol assay.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app