Duplex scan surveillance after carotid angioplasty and stenting: a rational definition of stent stenosis.

OBJECTIVE: A duplex ultrasound (DUS) surveillance algorithm used after carotid endarterectomy (CEA) was applied to patients after carotid stenting and angioplasty (CAS) to determine the incidence of high-grade stent stenosis, its relationship to clinical symptoms, and the outcome of reintervention.

METHODS: In 111 patients who underwent 114 CAS procedures for symptomatic (n = 62) or asymptomatic (n = 52) atherosclerotic or recurrent stenosis after CEA involving the internal carotid artery (ICA), DUS surveillance was performed 300 cm/s, diastolic velocity >125 cm/s, internal carotid artery stent/proximal common carotid artery ratio >4) involving the stented arterial segment prompted diagnostic angiography and repair when >75% diameter-reduction stenosis was confirmed. Criteria for >50% CAS stenosis was a PSV >150 cm/s with a PSV stent ratio >2.

RESULTS: All 114 carotid stents were patent on initial DUS imaging, including 90 (79%) with PSV <150 cm/s (94 +/- 24 cm/s), 23 (20%) with PSV >150 cm/s (183 +/- 34 cm/s), and one with high-grade, residual stenosis (PSV = 355). During subsequent surveillance, 81 CAS sites (71%) exhibited no change in stenosis severity, nine sites demonstrated stenosis regression to <50% diameter reduction, and five sites developed velocity spectra of a high-grade stenosis. Angiography confirmed >75% diameter reduction in all six CASs with DUS-detected high-grade stenosis, all patients were asymptomatic, and treatment consisted of endovascular (n = 5) or surgical (n = 1) repair. During the mean 33-month follow-up period, three patients experienced ipsilateral, reversible neurologic events at 30, 45, and 120 days after CAS; none was associated with severe stent stenosis. No stent occlusions occurred, and no patient with >50% CAS stenosis on initial or subsequent testing developed a permanent ipsilateral permanent neurologic deficit or stroke-related death.

CONCLUSION: DUS surveillance after CAS identified a 5% procedural failure rate due to the development of high-grade in-stent stenosis. Both progression and regression of stent stenosis severity was observed on serial testing, but 70% of CAS sites demonstrated velocity spectra consistent with <50% diameter reduction. The surveillance algorithm used, including reintervention for asymptomatic high-grade CAS stenosis, was associated with stent patency and the absence of disabling stroke.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app