JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

High-throughput DNA droplet assays using picoliter reactor volumes.

Analytical Chemistry 2007 September 2
The online characterization and detection of individual droplets at high speeds, low analyte concentrations, and perfect detection efficiencies is a significant challenge underpinning the application of microfluidic droplet reactors to high-throughput chemistry and biology. Herein, we describe the integration of confocal fluorescence spectroscopy as a high-efficiency detection method for droplet-based microfluidics. Issues such as surface contamination, rapid mixing, and rapid detection, as well as low detections limits have been addressed with the approach described when compared to conventional laminar flow-based fluidics. Using such a system, droplet size, droplet shape, droplet formation frequencies, and droplet compositions can be measured accurately and precisely at kilohertz frequencies. Taking advantage of this approach, we demonstrate a high-throughput biological assay based on fluorescence resonance energy transfer (FRET). By attaching a FRET donor (Alexa Fluor 488) to streptavidin and labeling a FRET acceptor (Alexa Fluor 647) on one DNA strand and biotin on the complementary strand, donor and acceptor molecules are brought in proximity due to streptavidin-biotin binding, resulting in FRET. Fluorescence bursts of the donor and acceptor from each droplet can be monitored simultaneously using separate avalanche photodiode detectors operating in single photon counting mode. Binding assays were investigated and compared between fixed streptavidin and DNA concentrations. Binding curves fit perfectly to Hill-Waud models, and the binding ratio between streptavidin and biotin was evaluated and found to be in agreement with the biotin binding sites on streptavidin. FRET efficiency for this FRET pair was also investigated from the binding results. Efficiency results show that this detection system can precisely measure FRET even at low FRET efficiencies.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app