Clinical evaluation of the FloTrac/Vigileo system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery.
British Journal of Anaesthesia 2007 September
BACKGROUND: Assessment of cardiac output (CO) by the FloTrac/Vigileo system may offer a less invasive means of determining the CO than either the pulmonary artery catheter (PAC) or the PiCCOplus system. The aim of this study was to compare CO measurements made using the FloTrac/Vigileo system with upgraded software (FCO, Edwards Lifesciences, Irvine CA, USA), the PiCCOplus system (PCO, Pulsion Medical Systems, Munich, Germany) and continuous CO monitoring using a PAC (CCO; Vigilance monitoring, Edwards Lifesciences, Irvine CA, USA) with intermittent pulmonary artery thermodilution (ICO). The study was conducted in patients undergoing elective cardiac surgery.
METHODS: Thirty-one patients with preserved left ventricular function were enrolled. CCO, FCO, and PCO were recorded in the perioperative period at six predefined time points after achieving stable haemodynamic conditions; ICO was determined from the mean of three bolus injections. Bland-Altman analysis was used to compare CCO, FCO, and PCO with ICO.
RESULTS: Bland-Altman analysis revealed a comparable mean bias and limits of agreement for all tested continuous CO monitoring devices using ICO as reference method. Agreement for all devices decreased in the postoperative period.
CONCLUSION: The performance of the FloTrac/Vigileo system, the PiCCOplus, and the Vigilance CCO monitoring for CO measurement were comparable when tested against intermittent thermodilution in patients undergoing elective cardiac surgery.
METHODS: Thirty-one patients with preserved left ventricular function were enrolled. CCO, FCO, and PCO were recorded in the perioperative period at six predefined time points after achieving stable haemodynamic conditions; ICO was determined from the mean of three bolus injections. Bland-Altman analysis was used to compare CCO, FCO, and PCO with ICO.
RESULTS: Bland-Altman analysis revealed a comparable mean bias and limits of agreement for all tested continuous CO monitoring devices using ICO as reference method. Agreement for all devices decreased in the postoperative period.
CONCLUSION: The performance of the FloTrac/Vigileo system, the PiCCOplus, and the Vigilance CCO monitoring for CO measurement were comparable when tested against intermittent thermodilution in patients undergoing elective cardiac surgery.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app