Add like
Add dislike
Add to saved papers

Synthetic 13C-dipeptide breath test for the rapid assessment of pancreatic exocrine insufficiency in rats.

OBJECTIVE: (13)C-breath tests have been investigated in order to assess pancreatic exocrine function using various (13)C-compounds, but they have not been accepted for routine clinical use. One of the barriers to their acceptance is that these tests are time-consuming and require up to several hours for breath collection. The purpose of this study was to design a novel (13)C-compound that would make a rapid (13)C-breath test for assessing exocrine pancreatic function possible.

MATERIAL AND METHODS: N-benzoyl-L-tyrosyl-1-(13)C-L-alanine was synthesized, and the characteristics of its cleavage in duodenal juice and in the duodenum of rats were examined. Thereafter, a (13)C-breath test was carried out in which N-benzoyl-L-tyrosyl-1-(13)C-L-alanine was given orally to pancreatic exocrine-insufficient and normal control rats.

RESULTS: N-benzoyl-L-tyrosyl-1-(13)C-L-alanine was readily cleaved and liberated 1-(13)C-L-alanine in the duodenal juice. Carboxypeptidase was a major contributor to the cleavage. When N-benzoyl-L-tyrosyl-1-(13)C-L-alanine was injected into the duodenum and orally administered to the rats, the (13)C atom% of CO(2) in breath increased rapidly. This indicated that N-benzoyl-L-tyrosyl-1-(13)C-L-alanine in the duodenum liberated (13)C-Ala on cleavage. (13)C-Ala is absorbed and metabolized to liberate (13)CO(2), which is exhaled. It was shown that the Delta(13)CO(2) ( per thousand) in the N-benzoyl-L-tyrosyl-1-(13)C-L-alanine breath test in the pancreatic exocrine-insufficient rats, in whom the absorption and metabolism of (13)C-Ala was unimpaired, was significantly lower than that in the control rats.

CONCLUSIONS: The rate of increase in the Delta(13)CO(2) ( per thousand) in the N-benzoyl-L-tyrosyl-1-(13)C-L-alanine breath test is expected to be proportional to the rate of N-benzoyl-L-tyrosyl-1-(13)C-L-alanine cleavage by pancreatic proteases in the duodenum. We propose the N-benzoyl-L-tyrosyl-1-(13)C-L-alanine breath test as a rapid test for assessing pancreatic exocrine function.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app