Clinical costs of feeding tube placement.

BACKGROUND: Although small-bore tube placement is common, insertion can lead to serious complications. We investigated the use of radiographs, fluoroscopy, feeding tubes, and complications associated with blind feeding-tube placement.

METHODS: The electronic and paper records of adult patients receiving a small-bore feeding tube in 2005 were retrospectively reviewed for the following variables: demographics, desired location (gastric or postpyloric), number of radiographs, number of tubes per individual, time interval between medical prescription, tube placement and delivery of the diet, complications, transport for fluoroscopy, and hospital location of placement (intensive care unit vs floor).

RESULTS: We identified 1822 tubes placed into 729 patients (male: 449, 61.6%; female: 280, 38.4%; median age: 59 years old, range 18-98). All tubes were placed by nurses unless fluoroscopically placed in radiology or placed after head and neck surgery in the operating room. An average of 2.5 (range 1-20) tubes was used per patient. A total of 2696 radiographs were obtained for an average of 3.7 (range 0-32) films per patient and 1.5 (range 0-11) per feeding tube. Successful placement was higher for intragastric (93.3%) than for postpyloric position (60.4%; p < .001). Fluoroscopy was needed in 18.6% of the patients, mostly for postpyloric insertion (p < .001). Respiratory tree misplacement occurred in 23 (3.2%) patients; 9 (1.2%) had a pneumothorax and 4 (0.5%) died. Patients with a malpositioned feeding tube underwent more tube insertions (6.8 +/- 5.4; range 2-20) than patients without complications (2.2 +/- 1.8; range 1-18; p < .001).

CONCLUSIONS: The incidence of airway misplacement of feeding tubes (3.2%) at a major tertiary referral university hospital was alarming. Mandatory radiographs may eliminate the risk of respiratory administration of feedings but not misplacements. The associated costs of radiographs, unsuccessful placements, fluoroscopy, and complications are significant. A solution to this problem will require focused attention and development of specific protocols, possibly using new technologies.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app