COMPARATIVE STUDY
JOURNAL ARTICLE
RANDOMIZED CONTROLLED TRIAL

The impact of positive end-expiratory pressure on functional residual capacity and ventilation homogeneity impairment in anesthetized children exposed to high levels of inspired oxygen

Britta S von Ungern-Sternberg, Adrian Regli, Andreas Schibler, Jürg Hammer, Franz J Frei, Thomas O Erb
Anesthesia and Analgesia 2007, 104 (6): 1364-8, table of contents
17513627

BACKGROUND: High fractions of inspired oxygen (Fio2) result in resorption atelectasis shortly after their application. However, the impact of different levels of Fio2 and their interaction with positive end-expiratory pressure (PEEP) on functional residual capacity (FRC) and ventilation distribution is unknown in anesthetized children. We hypothesized that the use of a Fio2 of 1.0 results in a decrease of FRC and ventilation homogeneity compared with that of a Fio2 of 0.3, and that this decrease is prevented by PEEP of 6-cm H2O compared to a PEEP of 3-cm H2O.

METHODS: Forty-six children (3-6 yr) without cardiopulmonary disease were randomly allocated to receive PEEP of 6-cm H2O (PEEP 6 group) during the entire study period or PEEP of 3-cm H2O (PEEP 3 group). The order of the Fio2 (0.3 or 1.0) was also randomized. A defined recruitment maneuver was performed after tracheal intubation and 5 min later the first measurement. This procedure was then repeated with the second Fio2 level. FRC and lung clearance index (LCI) were calculated by a blinded observer.

RESULTS: While FRC (mean +/- sd) was similar at both levels of Fio2 (0.3: 25.6 +/- 2.9 mL/kg vs 1.0: 25.6 +/- 2.8 mL/kg, P = 0.189) in the PEEP 6 group, FRC decreased in the PEEP 3 group (0.3: 24.9 +/- 3.8 vs 1.0: 21.7 +/- 4.1, P < 0.0001). Furthermore, with continuous PEEP of 6-cm H2O a similar LCI was observed at both levels of Fio2 (0.3: 6.45 +/- 0.4 vs 6.43 +/- 0.4, P = 0.668) while LCI increased at the higher Fio2 in the PEEP 3 group (0.3: 6.5 +/- 0.5 vs 1.0: 7.7 +/- 1.2, P < 0.0001).

CONCLUSIONS: During the application of a very low PEEP of 3-cm H2O, FRC and ventilation distribution decreased significantly at an Fio2 of 1.0 compared with that at an Fio2 of 0.3. This decrease could be counterbalanced by the administration of PEEP of 6-cm H2O, indicating that a low level of PEEP is sufficient to maintain FRC and ventilation distribution regardless of the oxygen concentration.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
17513627
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"