JOURNAL ARTICLE

PET-CT-based auto-contouring in non-small-cell lung cancer correlates with pathology and reduces interobserver variability in the delineation of the primary tumor and involved nodal volumes

Angela van Baardwijk, Geert Bosmans, Liesbeth Boersma, Jeroen Buijsen, Stofferinus Wanders, Monique Hochstenbag, Robert-Jan van Suylen, André Dekker, Cary Dehing-Oberije, Ruud Houben, Søren M Bentzen, Marinus van Kroonenburgh, Philippe Lambin, Dirk De Ruysscher
International Journal of Radiation Oncology, Biology, Physics 2007 July 1, 68 (3): 771-8
17398018

PURPOSE: To compare source-to-background ratio (SBR)-based PET-CT auto-delineation with pathology in non-small-cell lung cancer (NSCLC) and to investigate whether auto-delineation reduces the interobserver variability compared with manual PET-CT-based gross tumor volume (GTV) delineation.

METHODS AND MATERIALS: Source-to-background ratio-based auto-delineation was compared with macroscopic tumor dimensions to assess its validity in 23 tumors. Thereafter, GTVs were delineated manually on 33 PET-CT scans by five observers for the primary tumor (GTV-1) and the involved lymph nodes (GTV-2). The delineation was repeated after 6 months with the auto-contour provided. This contour was edited by the observers. For comparison, the concordance index (CI) was calculated, defined as the ratio of intersection and the union of two volumes (A intersection B)/(A union or logical sum B).

RESULTS: The maximal tumor diameter of the SBR-based auto-contour correlated strongly with the macroscopic diameter of primary tumors (correlation coefficient = 0.90) and was shown to be accurate for involved lymph nodes (sensitivity 67%, specificity 95%). The median auto-contour-based target volumes were smaller than those defined by manual delineation for GTV-1 (31.8 and 34.6 cm(3), respectively; p = 0.001) and GTV-2 (16.3 and 21.8 cm(3), respectively; p = 0.02). The auto-contour-based method showed higher CIs than the manual method for GTV-1 (0.74 and 0.70 cm(3), respectively; p < 0.001) and GTV-2 (0.60 and 0.51 cm(3), respectively; p = 0.11).

CONCLUSION: Source-to-background ratio-based auto-delineation showed a good correlation with pathology, decreased the delineated volumes of the GTVs, and reduced the interobserver variability. Auto-contouring may further improve the quality of target delineation in NSCLC patients.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
17398018
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"