COMPARATIVE STUDY
JOURNAL ARTICLE
RESEARCH SUPPORT, N.I.H., EXTRAMURAL
RESEARCH SUPPORT, NON-U.S. GOV'T
RESEARCH SUPPORT, U.S. GOV'T, NON-P.H.S.
Add like
Add dislike
Add to saved papers

Automated segmentation of the optic disc from stereo color photographs using physiologically plausible features.

PURPOSE: To evaluate a novel automated segmentation algorithm for cup-to-disc segmentation from stereo color photographs of patients with glaucoma for the measurement of glaucoma progression.

METHODS: Stereo color photographs of the optic disc were obtained by using a fixed stereo-base fundus camera in 58 eyes of 58 patients with suspected or open-angle glaucoma. Manual planimetry was performed by three glaucoma faculty members to delineate a reference standard rim and cup segmentation of all stereo pairs and by three glaucoma fellows as well. Pixel feature classification was evaluated on the stereo pairs and corresponding reference standard, by using feature computation based on simulation of photoreceptor color opponency and visual cortex simple and complex cells. An optimal subset of 12 features was used to segment all pixels in all stereo pairs, and the percentage of pixels assigned the correct class and linear cup-to-disc ratio (LCDR) estimates of the glaucoma fellows and the algorithm were compared to the reference standard.

RESULTS: The algorithm was able to assign cup, rim, and background correctly to 88% of all pixels. Correlations of the LCDR estimates of glaucoma fellows with those of the reference standard were 0.73 (95% CI, 0.58-0.83), 0.81 (95% CI, 0.70-0.89), and 0.86 (95% CI, 0.78-0.91), respectively, whereas the correlation of the algorithm with the reference standard was 0.93 (95% CI, 0.89-0.96; n = 58).

CONCLUSIONS: The pixel feature classification algorithm allows objective segmentation of the optic disc from conventional color stereo photographs automatically without human input. The performance of the disc segmentation and LCDR calculation of the algorithm was comparable to that of glaucoma fellows in training and is promising for objective evaluation of optic disc cupping.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app