Add like
Add dislike
Add to saved papers

Electrodeposition of Al in 1-butyl-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)amide and 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)amide ionic liquids: in situ STM and EQCM studies.

In the present paper, the electrodeposition of Al on flame-annealed Au(111) and polycrystalline Au substrates in two air- and water-stable ionic liquids namely, 1-butyl-1-methyl-pyrrolidinium bis(trifluoromethylsulfonyl)amide, [Py(1,4)]Tf(2)N, and 1-ethyl-3-methyl-imidazolium bis(trifluoromethylsulfonyl)amide, [EMIm]Tf(2)N, has been investigated by in situ scanning tunneling microscopy (STM), electrochemical quartz crystal microbalance (EQCM), and cyclic voltammetry. The cyclic voltammogram of aluminum deposition and stripping on Au(111) in the upper phase of the biphasic mixture of AlCl(3)/[EMIm]Tf(2)N at room temperature (25 degrees C) shows that the electrodeposition process is completely reversible as also evidenced by in situ STM and EQCM studies. Additionally, a cathodic peak at an electrode potential of about 0.55 V vs Al/Al(III) is correlated to the aluminum UPD process that was evidenced by in situ STM. A surface alloying of Al with Au at the early stage of deposition occurs. It has been found that the Au(111) surface is subject to a restructuring/reconstruction in the upper phase of the biphasic mixture of AlCl(3)/[Py(1,4)]Tf(2)N at room temperature (25 degrees C) and that the deposition is not fully reversible. Furthermore, the underpotential deposition of Al in [Py(1,4)]Tf(2)N is not as clear as in [EMIm]Tf(2)N. The frequency shift in the EQCM experiments in [Py(1,4)]Tf(2)N shows a surprising result as an increase in frequency and a decrease in damping with bulk aluminum deposition at potentials more negative than -1.8 V was observed at room temperature. However, at 100 degrees C there is a frequency decrease with ongoing Al deposition. At -2.0 V vs Al/Al(III), a bulk aluminum deposition sets in.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app