Balloon-based, circumferential, endoscopic radiofrequency ablation of Barrett's esophagus: 1-year follow-up of 100 patients.
Gastrointestinal Endoscopy 2007 Februrary
OBJECTIVE: To assess the dose-response, safety, and efficacy of circumferential endoscopic ablation of Barrett's esophagus (BE) by using an endoscopic balloon-based ablation device (HALO360 System).
DESIGN: This study was conducted in 2 serial phases (dosimetry phase and effectiveness phase) to evaluate a balloon-based ablation device that delivers a pre-set amount of energy density (J/cm2) to BE tissue. The dosimetry phase evaluated the dose-response and the safety of delivering 6 to 12 J/cm2. The effectiveness phase used 10 J/cm2 (delivered twice [x2]) for all patients, followed by EGD with biopsies at 1, 3, 6, and 12 months. A second ablation procedure was performed if BE was present at 1 or 3 months. Patients received esomeprazole 40 mg twice a day for 1 month after ablation, and 40 mg every day thereafter. Postablation symptoms were quantified by using a 14-day symptom diary (scale, 0-100). A complete response (CR) was defined as all biopsy specimens negative for BE at 12 months.
SETTING: Eight U.S. centers, between September 2003 and September 2005.
PATIENTS: Patients were 18 to 75 years of age, with a diagnosis of BE (without dysplasia), with histopathology reconfirmation of the diagnosis within 6 months of enrollment.
RESULTS: In the dosimetry phase, 32 patients (29 men; mean age, 56.8 years) were enrolled. Median symptom scores returned to a score of 0 of 100 by day 3. There were no dose-related serious adverse events, and the outcomes at 1 and 3 months permitted the selection of 10 J/cm2 (x2) for the subsequent effectiveness phase of the study. In the effectiveness phase, 70 patients (52 men, 18 women; mean age, 55.7 years) were enrolled. Median symptom scores returned to a score of 0 of 100 by day 4. At 12 months (n = 69; mean, 1.5 sessions), a CR for BE was achieved in 70% of patients. There were no strictures and no buried glandular mucosa in either study phase (4306 biopsy fragments evaluated).
CONCLUSIONS: Circumferential ablation of nondysplastic BE by using this balloon-based ablation device can be performed with no subsequent strictures or buried glands and with complete elimination of BE in 70% of patients at 1-year follow-up.
DESIGN: This study was conducted in 2 serial phases (dosimetry phase and effectiveness phase) to evaluate a balloon-based ablation device that delivers a pre-set amount of energy density (J/cm2) to BE tissue. The dosimetry phase evaluated the dose-response and the safety of delivering 6 to 12 J/cm2. The effectiveness phase used 10 J/cm2 (delivered twice [x2]) for all patients, followed by EGD with biopsies at 1, 3, 6, and 12 months. A second ablation procedure was performed if BE was present at 1 or 3 months. Patients received esomeprazole 40 mg twice a day for 1 month after ablation, and 40 mg every day thereafter. Postablation symptoms were quantified by using a 14-day symptom diary (scale, 0-100). A complete response (CR) was defined as all biopsy specimens negative for BE at 12 months.
SETTING: Eight U.S. centers, between September 2003 and September 2005.
PATIENTS: Patients were 18 to 75 years of age, with a diagnosis of BE (without dysplasia), with histopathology reconfirmation of the diagnosis within 6 months of enrollment.
RESULTS: In the dosimetry phase, 32 patients (29 men; mean age, 56.8 years) were enrolled. Median symptom scores returned to a score of 0 of 100 by day 3. There were no dose-related serious adverse events, and the outcomes at 1 and 3 months permitted the selection of 10 J/cm2 (x2) for the subsequent effectiveness phase of the study. In the effectiveness phase, 70 patients (52 men, 18 women; mean age, 55.7 years) were enrolled. Median symptom scores returned to a score of 0 of 100 by day 4. At 12 months (n = 69; mean, 1.5 sessions), a CR for BE was achieved in 70% of patients. There were no strictures and no buried glandular mucosa in either study phase (4306 biopsy fragments evaluated).
CONCLUSIONS: Circumferential ablation of nondysplastic BE by using this balloon-based ablation device can be performed with no subsequent strictures or buried glands and with complete elimination of BE in 70% of patients at 1-year follow-up.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app