Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge.

OBJECTIVE: Values of central venous pressure of 8-12 mm Hg and of pulmonary artery occlusion pressure of 12-15 mm Hg have been proposed as volume resuscitation targets in recent international guidelines on management of severe sepsis. By analyzing a large number of volume challenges, our aim was to test the significance of the recommended target values in terms of prediction of volume responsiveness.

DESIGN: Retrospective study.

SETTING: A 24-bed medical intensive care unit.

PATIENTS: All consecutive septic patients monitored with a pulmonary artery catheter who underwent a volume challenge between 2001 and 2004.

INTERVENTION: None.

MEASUREMENTS AND MAIN RESULTS: A total of 150 volume challenges in 96 patients were reviewed. In 65 instances, the volume challenge resulted in an increase in cardiac index of > or =15% (responders). The pre-infusion central venous pressure was similar in responders and nonresponders (8 +/- 4 vs. 9 +/- 4 mm Hg). The pre-infusion pulmonary artery occlusion pressure was slightly lower in responders (10 +/- 4 vs. 11 +/- 4 mm Hg, p < .05). However, the significance of pulmonary artery occlusion pressure to predict fluid responsiveness was poor and similar to that of central venous pressure, as indicated by low values of areas under the receiver operating characteristic curves (0.58 and 0.63, respectively). A central venous pressure of <8 mm Hg and a pulmonary artery occlusion pressure of <12 mm Hg predicted volume responsiveness with a positive predictive value of only 47% and 54%, respectively. With the knowledge of a low stroke volume index (<30 mL.m), their positive predictive values were still unsatisfactory: 61% and 69%, respectively. When the combination of central venous pressure and pulmonary artery occlusion pressure was considered instead of either pressure alone, the degree of prediction of volume responsiveness was not improved.

CONCLUSION: Our study demonstrates that cardiac filling pressures are poor predictors of fluid responsiveness in septic patients. Therefore, their use as targets for volume resuscitation must be discouraged, at least after the early phase of sepsis has concluded.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app