Respiratory variations in pulse oximeter waveform amplitude are influenced by venous return in mechanically ventilated patients under general anaesthesia.
European Journal of Anaesthesiology 2007 March
BACKGROUND AND OBJECTIVES: Respiratory variations in pulse oximetry plethysmographic waveform amplitude (DeltaPOP) are related to respiratory variations in arterial pulse pressure (DeltaPP) in the critical care setting. The aims of this study were to test the hypothesis that in mechanically ventilated patients undergoing general anaesthesia, DeltaPOP calculation is feasible and can detect changes in preload.
METHODS: Twenty-five mechanically ventilated patients were studied immediately after induction of general anaesthesia. Haemodynamic data (mean arterial pressure [MAP], central venous pressure [CVP], DeltaPP and DeltaPOP) were recorded at baseline, before and after tilting the patient from anti-Trendelenburg to Trendelenburg position in order to induce preload changes.
RESULTS: Change from anti-Trendelenburg to Trendelenburg position induced changes in MAP (58 +/- 9 to 67 +/- 10 mmHg, P < 0.05), CVP (4 +/- 4 to 13 +/- 5 mmHg, P < 0.05), DeltaPP (14 +/- 8 to 7 +/- 5%, P < 0.05) and DeltaPOP (17 +/- 12 to 9 +/- 5%, P < 0.05). There was a significant relationship between DeltaPOP in anti-Trendelenburg position and percent change in MAP after volume expansion (r = 0.82; P < 0.05).
CONCLUSIONS: DeltaPOP can be determined in the operating room and is influenced by changes in preload. This new index has potential clinical applications for the prediction of fluid responsiveness.
METHODS: Twenty-five mechanically ventilated patients were studied immediately after induction of general anaesthesia. Haemodynamic data (mean arterial pressure [MAP], central venous pressure [CVP], DeltaPP and DeltaPOP) were recorded at baseline, before and after tilting the patient from anti-Trendelenburg to Trendelenburg position in order to induce preload changes.
RESULTS: Change from anti-Trendelenburg to Trendelenburg position induced changes in MAP (58 +/- 9 to 67 +/- 10 mmHg, P < 0.05), CVP (4 +/- 4 to 13 +/- 5 mmHg, P < 0.05), DeltaPP (14 +/- 8 to 7 +/- 5%, P < 0.05) and DeltaPOP (17 +/- 12 to 9 +/- 5%, P < 0.05). There was a significant relationship between DeltaPOP in anti-Trendelenburg position and percent change in MAP after volume expansion (r = 0.82; P < 0.05).
CONCLUSIONS: DeltaPOP can be determined in the operating room and is influenced by changes in preload. This new index has potential clinical applications for the prediction of fluid responsiveness.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app