We have located links that may give you full text access.
CLINICAL TRIAL
JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Peak exercise capacity estimated from incremental shuttle walking test in patients with COPD: a methodological study.
Respiratory Research 2006
BACKGROUND: In patients with COPD, both laboratory exercise tests and field walking tests are used to assess physical performance. In laboratory tests, peak exercise capacity in watts (W peak) and/or peak oxygen uptake (VO2 peak) are assessed, whereas the performance on walking tests usually is expressed as distance walked. The aim of the study was to investigate the relationship between an incremental shuttle walking test (ISWT) and two laboratory cycle tests in order to assess whether W peak could be estimated from an ISWT.
METHODS: Ninety-three patients with moderate or severe COPD performed an ISWT, an incremental cycle test (ICT) to measure W peak and a semi-steady-state cycle test with breath-by-breath gas exchange analysis (CPET) to measure VO2 peak. Routine equations for conversion between cycle tests were used to estimate W peak from measured VO2 peak (CPET). Conversion equation for estimation of W peak from ISWT was found by univariate regression.
RESULTS: There was a significant correlation between W peak and distance walked on ISWT x body weight (r = 0.88, p < 0.0001). The agreement between W peak measured by ICT and estimated from ISWT was similar to the agreement between measured W peak (ICT) and W peak estimated from measured VO2 peak by CPET.
CONCLUSION: Peak exercise capacity measured by an incremental cycle test could be estimated from an ISWT with similar accuracy as when estimated from peak oxygen uptake in patients with COPD.
METHODS: Ninety-three patients with moderate or severe COPD performed an ISWT, an incremental cycle test (ICT) to measure W peak and a semi-steady-state cycle test with breath-by-breath gas exchange analysis (CPET) to measure VO2 peak. Routine equations for conversion between cycle tests were used to estimate W peak from measured VO2 peak (CPET). Conversion equation for estimation of W peak from ISWT was found by univariate regression.
RESULTS: There was a significant correlation between W peak and distance walked on ISWT x body weight (r = 0.88, p < 0.0001). The agreement between W peak measured by ICT and estimated from ISWT was similar to the agreement between measured W peak (ICT) and W peak estimated from measured VO2 peak by CPET.
CONCLUSION: Peak exercise capacity measured by an incremental cycle test could be estimated from an ISWT with similar accuracy as when estimated from peak oxygen uptake in patients with COPD.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app