JOURNAL ARTICLE

Noninvasive reconstruction of three-dimensional ventricular activation sequence from the inverse solution of distributed equivalent current density

Zhongming Liu, Chenguang Liu, Bin He
IEEE Transactions on Medical Imaging 2006, 25 (10): 1307-18
17024834
We propose a new electrocardiographic (ECG) inverse approach for imaging the three-dimensional (3-D) ventricular activation sequence based on the modeling and estimation of the equivalent current density throughout the entire volume of the ventricular myocardium. The spatio-temporal coherence of the ventricular excitation process has been utilized to derive the activation time from the estimated time course of the equivalent current density. In the present study, we explored four different linear inverse algorithms (the minimum norm and weighted minimum norm estimates in combination with two regularization schemes: the instant-by-instant regularization and the isotropy method) to estimate the current density at each time instant during the ventricular depolarization. The activation time at any given location within the ventricular myocardium was determined as the time point with the occurrence of the maximum local current density estimate. Computer simulations were performed to evaluate this approach using single- and dual-site pacing protocols in a physiologically realistic cellular automaton heart model. The performance and stability of the proposed approach was evaluated with respect to the various levels of measurement noise (0, 5, 10, 20, 40, and 60 microV), the various numbers of ECG electrodes and the modeling errors on the torso geometry and heart position. The simulation results demonstrate that: 1) the single-site paced 3-D activation sequence can be well reconstructed from 200-channel body surface potential maps with additive Gaussian white noise of 20 microV (correlation coefficient = 0.90, relative error = 0.19, and localization error = 5.49 mm); 2) a higher imaging accuracy can be obtained when the activation is initiated from the left/right ventricle (LV/RV) compared to from the septum; 3) the isotropy method gives rise to a better performance than the conventional instant-by-instant regularization; 4) a decreased imaging accuracy results from a larger noise level, a fewer number of electrodes, or the volume conductor modeling errors; however, a reasonable imaging accuracy can still be obtained with a 60 microV noise level, 64 electrodes, or mild errors on both the torso geometry and heart position, respectively; 5) the dual-site paced 3-D activation sequence can be imaged when the two sites are paced either simultaneously or with a time delay of 20 ms; 6) two pacing sites can be resolved and localized in the imaged 3-D activation sequence when they are located at the contralateral sides of ventricles or at the ventricular lateral wall and the apex, respectively.

Comments

You need to log in or sign up for an account to be able to comment.

No comments yet, be the first to post one!

Related Papers

Available on the App Store

Available on the Play Store
Remove bar
Read by QxMD icon Read
17024834
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"