Submaximal exercise testing in the assessment of interstitial lung disease secondary to systemic sclerosis: reproducibility and correlations of the 6-min walk test.
Annals of the Rheumatic Diseases 2007 Februrary
BACKGROUND: The 6-min walk test (6MWT) is increasingly used as an outcome measure in interstitial lung disease (ILD).
AIM: To evaluate the usefulness of the 6MWT in a cohort of patients with ILD secondary to systemic sclerosis (SSc) and to correlate with established physiological parameters.
METHODS: 163 patients with SSc-ILD were recruited for a multicentre, randomised, double-blind clinical trial. Available data at protocol screening included repeated 6MWTs, pulmonary function testing with diffusing capacity, Doppler echocardiography and high-resolution computed tomography of the thorax. Borg Dyspnoea Index was evaluated before and after 6MWT.
RESULTS: Mean (standard deviation (SD)) distance walked during walk test 1 was 396.6 (84.55) m compared with 399.5 (86.28) m at walk test 2. The within-subject, intertest correlation as determined by Pearson's correlation coefficient testing was 0.95 (p<0.001). However, only weak correlations of 6MWT with percentage forced vital capacity and the Borg Dyspnoea Index were observed, and no correlation was observed with percentage diffusing capacity.
CONCLUSION: These data confirm the high reproducibility of the 6MWT in patients with SSc-ILD and therefore the validity of the test in this cohort. The lack of correlation of 6MWT with standard physiological parameters of ILD suggests a multifactorial basis for limited exercise capacity in patients with SSc and calls into question the utility of the 6MWT as a measure of outcome in future studies on SSc-ILD.
AIM: To evaluate the usefulness of the 6MWT in a cohort of patients with ILD secondary to systemic sclerosis (SSc) and to correlate with established physiological parameters.
METHODS: 163 patients with SSc-ILD were recruited for a multicentre, randomised, double-blind clinical trial. Available data at protocol screening included repeated 6MWTs, pulmonary function testing with diffusing capacity, Doppler echocardiography and high-resolution computed tomography of the thorax. Borg Dyspnoea Index was evaluated before and after 6MWT.
RESULTS: Mean (standard deviation (SD)) distance walked during walk test 1 was 396.6 (84.55) m compared with 399.5 (86.28) m at walk test 2. The within-subject, intertest correlation as determined by Pearson's correlation coefficient testing was 0.95 (p<0.001). However, only weak correlations of 6MWT with percentage forced vital capacity and the Borg Dyspnoea Index were observed, and no correlation was observed with percentage diffusing capacity.
CONCLUSION: These data confirm the high reproducibility of the 6MWT in patients with SSc-ILD and therefore the validity of the test in this cohort. The lack of correlation of 6MWT with standard physiological parameters of ILD suggests a multifactorial basis for limited exercise capacity in patients with SSc and calls into question the utility of the 6MWT as a measure of outcome in future studies on SSc-ILD.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app