JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Near infrared spectroscopy, cluster and multivariate analysis hyphenated to thin layer chromatography for the analysis of amino acids.

Amino Acids 2006 July
A method based on near-infrared spectroscopy (NIRS) was developed for the rapid and non-destructive determination and quantification of solid and dissolved amino acids. The statistical results obtained after optimisation of measurement conditions were evaluated on the basis of statistical parameters, Q-value (quality of calibrations), R(2), standard error of estimation (SEE), standard error of prediction (SEP), BIAS applying cluster and different multivariate analytical procedures. Experimental optimisation comprised the selection of the highest suitable optical thin-layer (0.5, 1.0, 1.5, 2.0, 2.5, 3.0 mm), sample temperature (10-30 degrees C), measurement option (light fibre, 0.5 mm optical thin-layer; boiling point tube; different types of cuvettes) and sample concentration in the range between 100 and 500 ppm. Applying the optimised conditions and a 115-QS Suprasil cuvette (V = 400 microl), the established qualitative model enabled to distinguish between different dissolved amino acids with a Q-value of 0.9555. Solid amino acids were investigated in the transflectance mode, allowing to differentiate them with a Q-value of 0.9155. For the qualitative and quantitative analysis of amino acids in complex matrices NIRS was established as a detection system directly onto the plate after prior separation on cellulose based thin-layer chromatography (TLC) sheets employing n-butanol, acetic acid and distilled water at a ratio of 8:4:2 (v/v/v) as an optimised mobile phase. Due to the prior separation step, the established calibration curve was found to be more stable than the one calculated from the dissolved amino acids. The found lower limit of detection was 0.01 mg/ml. Finally, this optimised TLC-NIRS method was successfully applied for the qualitative and quantitative analysis of L-lysine in apple juice. NIRS is shown not only to offer a fast, non-destructive detection tool but also to provide an easy-to-use alternative to more complicated detection methods such as mass spectrometry (MS) for qualitative and quantitative TLC analysis of amino acids in crude samples.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app