Doppler ultrasonography versus amniocentesis to predict fetal anemia.

BACKGROUND: Pregnancies complicated by Rh alloimmunization have been evaluated with the use of serial invasive amniocentesis to determine bilirubin levels by measuring in the amniotic fluid the change in optical density at a wavelength of 450 nm (DeltaOD450); however, this procedure carries risks. Noninvasive Doppler ultrasonographic measurement of the peak velocity of systolic blood flow in the middle cerebral artery also predicts severe fetal anemia, but this test has not been rigorously evaluated in comparison with amniotic-fluid DeltaOD450.

METHODS: We performed a prospective, international, multicenter study including women with RhD-, Rhc-, RhE-, or Fy(a)-alloimmunized pregnancies with indirect antiglobulin titers of at least 1:64 and antigen-positive fetuses to assess whether Doppler ultrasonographic measurement of the peak systolic velocity of blood flow in the middle cerebral artery was at least as sensitive and accurate as measurement of amniotic-fluid DeltaOD450 for diagnosing severe fetal anemia. The results of the two tests were compared with the incidence of fetal anemia, as determined by measurement of hemoglobin levels in fetal blood.

RESULTS: Of 165 fetuses, 74 had severe anemia. For the detection of severe fetal anemia, Doppler ultrasonography of the middle cerebral artery had a sensitivity of 88 percent (95 percent confidence interval, 78 to 93 percent), a specificity of 82 percent (95 percent confidence interval, 73 to 89 percent), and an accuracy of 85 percent (95 percent confidence interval, 79 to 90 percent). Amniotic-fluid DeltaOD450 had a sensitivity of 76 percent (95 percent confidence interval, 65 to 84 percent), a specificity of 77 percent (95 percent confidence interval, 67 to 84 percent), and an accuracy of 76 percent (95 percent confidence interval, 69 to 82 percent). Doppler ultrasonography was more sensitive, by 12 percentage points (95 percent confidence interval, 0.3 to 24.0), and more accurate, by 9 percentage points (95 percent confidence interval, 1.1 to 15.9), than measurement of amniotic-fluid DeltaOD450.

CONCLUSIONS: Doppler measurement of the peak velocity of systolic blood flow in the middle cerebral artery can safely replace invasive testing in the management of Rh-alloimmunized pregnancies. (ClinicalTrials.gov number, NCT00295516.).

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Group 7SearchHeart failure treatmentPapersTopicsCollectionsEffects of Sodium-Glucose Cotransporter 2 Inhibitors for the Treatment of Patients With Heart Failure Importance: Only 1 class of glucose-lowering agents-sodium-glucose cotransporter 2 (SGLT2) inhibitors-has been reported to decrease the risk of cardiovascular events primarily by reducingSeptember 1, 2017: JAMA CardiologyAssociations of albuminuria in patients with chronic heart failure: findings in the ALiskiren Observation of heart Failure Treatment study.CONCLUSIONS: Increased UACR is common in patients with heart failure, including non-diabetics. Urinary albumin creatininineJul, 2011: European Journal of Heart FailureRandomized Controlled TrialEffects of Liraglutide on Clinical Stability Among Patients With Advanced Heart Failure and Reduced Ejection Fraction: A Randomized Clinical Trial.Review

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app