Diagnostic accuracy of transesophageal echocardiography, helical computed tomography, and magnetic resonance imaging for suspected thoracic aortic dissection: systematic review and meta-analysis.

BACKGROUND: Patients with suspected thoracic aortic dissection require early and accurate diagnosis. Aortography has been replaced by less invasive imaging techniques including transesophageal echocardiography (TEE), helical computed tomography (CT), and magnetic resonance imaging (MRI); however, accuracies have varied from trial to trial, and which imaging technique should be applied to which risk population remains unclear. We systematically reviewed the diagnostic accuracy of these imaging techniques in patients with suspected thoracic aortic dissection.

METHODS: Published English-language reports on the diagnosis of thoracic aortic dissection by TEE, helical CT, or MRI were identified from electronic databases. Sensitivity, specificity, and positive and negative likelihood ratios were pooled in a random-effects model.

RESULTS: Sixteen studies involving a total of 1139 patients were selected. Pooled sensitivity (98%-100%) and specificity (95%-98%) were comparable between imaging techniques. The pooled positive likelihood ratio appeared to be higher for MRI (positive likelihood ratio, 25.3; 95% confidence interval, 11.1-57.1) than for TEE (14.1; 6.0-33.2) or helical CT (13.9; 4.2-46.0). If a patient had shown a 50% pretest probability of thoracic aortic dissection (high risk), he or she had a 93% to 96% posttest probability of thoracic aortic dissection following a positive result of each imaging test. If a patient had a 5% pretest probability of thoracic aortic dissection (low risk), he or she had a 0.1% to 0.3% posttest probability of thoracic aortic dissection following a negative result of each imaging test.

CONCLUSION: All 3 imaging techniques, ie, TEE, helical CT, and MRI, yield clinically equally reliable diagnostic values for confirming or ruling out thoracic aortic dissection.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app