Electrical isolation of pulmonary veins in patients with atrial fibrillation: reduction of fluoroscopy exposure and procedure duration by the use of a non-fluoroscopic navigation system (NavX)

Heidi Luise Estner, Isabel Deisenhofer, Armin Luik, Gjin Ndrepepa, Christian von Bary, Bernhard Zrenner, Claus Schmitt
Europace: European Pacing, Arrhythmias, and Cardiac Electrophysiology 2006, 8 (8): 583-7
16831837

AIMS: The aim of the study was to investigate the feasibility of performing segmental pulmonary vein (PV) isolation guided by the NavX (Endocardial Solutions, St Jude Medical, Inc., St Paul, MN, USA) system without the three-dimensional (3D) geometric reconstruction option and whether the use of NavX system will reduce the radiation exposure and procedure duration.

METHODS AND RESULTS: The study included 64 patients with symptomatic paroxysmal or permanent atrial fibrillation, in whom PV isolation was performed using fluoroscopic guidance (n=32) or the NavX system (n=32). Pulmonary vein mapping with a circular mapping catheter allowed the identification and localization of myocardial connections between the PV and the left atrium. PV isolation was performed by radiofrequency ablation of these connections at the atrial aspect of the PV ostium. Primary success rate for isolated PVs did not differ significantly in patients ablated under fluoroscopic guidance vs. those ablated under guidance of NavX system [100/107 PVs (93.5%) vs. 120/124 PV (96.8%; P=n.s.)]. Compared with fluoroscopy guided procedures, NavX-guided procedures showed a significant reduction in the fluoroscopy time (75.8+/-24.5 vs. 38.9+/-19.3 min, P<0.05), total X-ray exposure (93.2+/-51.6 vs. 56.6+/-37.9 Gy cm(2), P=0.03), and total procedural time (237.7+/-65.4 vs. 188.6+/-62.7 min, P=0.01). The mean follow-up was 9.5+/-3.0 months. One patient in each group was lost to follow-up. Seven-day Holter monitoring showed that 23 of 31 patients (74.2%) in the NavX-guided group and 21 of 31 patients (67.7%) in the fluoroscopy-guided group were in sinus rhythm (P=0.57).

CONCLUSION: The 3D visualization of the catheters by NavX system allows a rapid and precise visualization of the mapping and ablation catheters at the PV ostia and markedly reduces fluoroscopy time, total X-ray exposure, and procedural duration during PV isolation compared with ablation performed under fluoroscopy guidance.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
16831837
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"