Spine 2006 July 2
STUDY DESIGN: We evaluated the trajectories of atlantoaxial transarticular and C2-pedicle screws in 3 dimensions using computerized tomography.
OBJECTIVE: To compare the anatomic risk for vertebral artery injury associated with C2-pedicle and atlantoaxial transarticular screws.
SUMMARY OF BACKGROUND DATA: The atlantoaxial fixation technique using C1-lateral mass screws combined with C2-pedicle screws is considered a safer technique for preventing vertebral artery injury than atlantoaxial transarticular fixation. However, few reports have compared the anatomic risk of vertebral artery injury associated with C2-pedicle screws with that of transarticular screws.
METHODS: A total of 62 consecutive patients with cervical lesions were evaluated using 3-dimensional images reconstructed by a computer-assisted navigation system. We compared the maximum possible diameters of the atlantoaxial transarticular screw and C2-pedicle screw trajectories, and examined whether the maximum possible diameters were limited by the height or width of the bony structure in screw trajectories < or = 4 mm in diameter.
RESULTS: Mean maximum possible diameters did not differ significantly between the trajectories of 124 atlantoaxial transarticular and 124 C2-pedicle screws. In screw trajectories < or = 4 mm in diameter, 57.1% of transarticular screw trajectories were limited by the height of the bony structure, and all pedicle screw trajectories were limited by the width.
CONCLUSIONS: C2-pedicle screw placement has nearly the same anatomic risk of vertebral artery injury as transarticular screw placement. Preoperative 3-dimensional evaluation may be useful for choosing the best surgical technique.
OBJECTIVE: To compare the anatomic risk for vertebral artery injury associated with C2-pedicle and atlantoaxial transarticular screws.
SUMMARY OF BACKGROUND DATA: The atlantoaxial fixation technique using C1-lateral mass screws combined with C2-pedicle screws is considered a safer technique for preventing vertebral artery injury than atlantoaxial transarticular fixation. However, few reports have compared the anatomic risk of vertebral artery injury associated with C2-pedicle screws with that of transarticular screws.
METHODS: A total of 62 consecutive patients with cervical lesions were evaluated using 3-dimensional images reconstructed by a computer-assisted navigation system. We compared the maximum possible diameters of the atlantoaxial transarticular screw and C2-pedicle screw trajectories, and examined whether the maximum possible diameters were limited by the height or width of the bony structure in screw trajectories < or = 4 mm in diameter.
RESULTS: Mean maximum possible diameters did not differ significantly between the trajectories of 124 atlantoaxial transarticular and 124 C2-pedicle screws. In screw trajectories < or = 4 mm in diameter, 57.1% of transarticular screw trajectories were limited by the height of the bony structure, and all pedicle screw trajectories were limited by the width.
CONCLUSIONS: C2-pedicle screw placement has nearly the same anatomic risk of vertebral artery injury as transarticular screw placement. Preoperative 3-dimensional evaluation may be useful for choosing the best surgical technique.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app