We have located links that may give you full text access.
JOURNAL ARTICLE
RANDOMIZED CONTROLLED TRIAL
Ultra-low dose combined spinal-epidural anesthesia with intrathecal bupivacaine 3.75 mg for cesarean delivery: a randomized controlled trial.
International Journal of Obstetric Anesthesia 2006 October
BACKGROUND: We wished to investigate the feasibility of an ultra low-dose combined spinal-epidural technique in providing surgical anesthesia for uncomplicated cesarean deliveries in a randomized, double-blind controlled trial.
METHOD: Forty-four normotensive, non-obese patients were randomized to receive either intrathecal hyperbaric bupivacaine 3.75 mg (low dose group, n=22) or 9 mg (conventional group, n=22), in addition to intrathecal fentanyl 25 microg, morphine 100 microg, and epidural 1.5% lidocaine 3 mL. Sensorimotor anesthesia and hemodynamic data were assessed at 2.5-min intervals for the first 15 min.
RESULTS: The maximal sensory block achieved in the low-dose group was significantly lower than that in the conventional group (median T3, [range T2-T6] vs. T2 [C2-T6], P<0.001) with a longer time taken to reach maximal sensory block. The low-dose group had less motor block, faster sensory regression to T10 dermatome and faster motor recovery to Bromage 0 (all P<0.001). The block failed to reach T6 bilaterally within 10 min in one patient in the low-dose group and two in the conventional group, with no significant difference in the need for epidural supplementation before or after delivery of the baby. The low-dose group experienced less hypotension (14% vs. 73%, P<0.001) with less ephedrine usage (0.68 vs. 17.5 mg, P<0.001). There was no difference in operating conditions and other side effects (shivering, pruritus).
CONCLUSION: We conclude that this technique results in a significantly lower incidence of maternal hypotension and has a role in high-risk parturients in whom maintenance of stable hemodynamics is imperative.
METHOD: Forty-four normotensive, non-obese patients were randomized to receive either intrathecal hyperbaric bupivacaine 3.75 mg (low dose group, n=22) or 9 mg (conventional group, n=22), in addition to intrathecal fentanyl 25 microg, morphine 100 microg, and epidural 1.5% lidocaine 3 mL. Sensorimotor anesthesia and hemodynamic data were assessed at 2.5-min intervals for the first 15 min.
RESULTS: The maximal sensory block achieved in the low-dose group was significantly lower than that in the conventional group (median T3, [range T2-T6] vs. T2 [C2-T6], P<0.001) with a longer time taken to reach maximal sensory block. The low-dose group had less motor block, faster sensory regression to T10 dermatome and faster motor recovery to Bromage 0 (all P<0.001). The block failed to reach T6 bilaterally within 10 min in one patient in the low-dose group and two in the conventional group, with no significant difference in the need for epidural supplementation before or after delivery of the baby. The low-dose group experienced less hypotension (14% vs. 73%, P<0.001) with less ephedrine usage (0.68 vs. 17.5 mg, P<0.001). There was no difference in operating conditions and other side effects (shivering, pruritus).
CONCLUSION: We conclude that this technique results in a significantly lower incidence of maternal hypotension and has a role in high-risk parturients in whom maintenance of stable hemodynamics is imperative.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app