EVALUATION STUDIES
JOURNAL ARTICLE
MULTICENTER STUDY
Add like
Add dislike
Add to saved papers

Procalcitonin is not sufficiently reliable to be the sole marker of neonatal sepsis of nosocomial origin.

BMC Pediatrics 2006 May 19
BACKGROUND: It has recently been suggested that serum procalcitonin (PCT) is of value in the diagnosis of neonatal sepsis, with varying results. The aim of this prospective multicenter study was to assess the usefulness of PCT as a marker of neonatal sepsis of nosocomial origin.

METHODS: One hundred infants aged between 4 and 28 days of life admitted to the Neonatology Services of 13 acute-care teaching hospitals in Spain over 1-year with clinical suspicion of neonatal sepsis of nosocomial origin were included in the study. Serum PCT concentrations were determined by a specific immunoluminometric assay. The reliability of PCT for the diagnosis of nosocomial neonatal sepsis at the time of suspicion of infection and at 12-24 h and 36-48 h after the onset of symptoms was calculated by receiver-operating characteristics (ROC) curves. The Youden's index (sensitivity + specificity - 1) was used for determination of optimal cutoff values of the diagnostic tests in the different postnatal periods. Sensitivity, specificity, and the likelihood ratio of a positive and negative result with the 95% confidence interval (CI) were calculated.

RESULTS: The diagnosis of nosocomial sepsis was confirmed in 61 neonates. Serum PCT concentrations were significantly higher at initial suspicion and at 12-24 h and 36-48 h after the onset of symptoms in neonates with confirmed sepsis than in neonates with clinically suspected but not confirmed sepsis. Optimal PCT thresholds according to ROC curves were 0.59 ng/mL at the time of suspicion of sepsis (sensitivity 81.4%, specificity 80.6%); 1.34 ng/mL within 12-24 h of birth (sensitivity 73.7%, specificity 80.6%), and 0.69 ng/mL within 36-48 h of birth (sensitivity 86.5%, specificity 72.7%).

CONCLUSION: Serum PCT concentrations showed a moderate diagnostic reliability for the detection of nosocomial neonatal sepsis from the time of suspicion of infection. PCT is not sufficiently reliable to be the sole marker of sepsis, but would be useful as part of a full sepsis evaluation.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app