JOURNAL ARTICLE
RESEARCH SUPPORT, N.I.H., EXTRAMURAL
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Emergence of community-acquired methicillin-resistant Staphylococcus aureus USA 300 clone as the predominant cause of skin and soft-tissue infections.

BACKGROUND: Studies have shown that community-acquired methicillin-resistant Staphylococcus aureus (MRSA) causes S. aureus skin and soft-tissue infection in selected populations.

OBJECTIVE: To determine the proportion of infections caused by community-acquired MRSA, the clinical characteristics associated with community-acquired MRSA, and the molecular epidemiology of community-acquired MRSA among persons with community-onset S. aureus skin and soft-tissue infection.

DESIGN: Active, prospective laboratory surveillance to identify S. aureus recovered from skin and soft-tissue sources.

SETTING: 1000-bed urban hospital and its affiliated outpatient clinics in Atlanta, Georgia.

PATIENTS: 384 persons with microbiologically confirmed community-onset S. aureus skin and soft-tissue infection.

MEASUREMENTS: Proportion of infections caused by and clinical factors associated with community-acquired MRSA among persons with community-onset S. aureus skin and soft-tissue infection. Pulsed-field gel electrophoresis and antimicrobial susceptibility patterns were used to epidemiologically classify community-onset S. aureus infections. Community-acquired MRSA was defined by MRSA isolates that either demonstrated a USA 300 or USA 400 pulsed-field type or had a susceptibility pattern showing resistance only to beta-lactams and erythromycin (for isolates not available for pulsed-field gel electrophoresis).

RESULTS: Community-onset skin and soft-tissue infection due to S. aureus was identified in 389 episodes, with MRSA accounting for 72% (279 of 389 episodes). Among all S. aureus isolates, 63% (244 of 389 isolates) were community-acquired MRSA. Among MRSA isolates, 87% (244 of 279 isolates) were community-acquired MRSA. When analysis was restricted only to MRSA isolates that were available for pulsed-field gel electrophoresis, 91% (159 of 175 isolates) had a pulsed-field type consistent with community-acquired MRSA; of these, 99% (157 of 159 isolates) were the MRSA USA 300 clone. Factors independently associated with community-acquired MRSA infection were black race (prevalence ratio, 1.53 [95% CI, 1.16 to 2.02]), female sex (prevalence ratio, 1.16 [CI, 1.02 to 1.32]), and hospitalization within the previous 12 months (prevalence ratio, 0.80 [CI, 0.66 to 0.97]). Inadequate initial antibiotic therapy was statistically significantly more common among those with community-acquired MRSA (65%) than among those with methicillin-susceptible S. aureus skin and soft-tissue infection (1%).

LIMITATIONS: Some MRSA isolates were not available for molecular typing.

CONCLUSIONS: The community-acquired MRSA USA 300 clone was the predominant cause of community-onset S. aureus skin and soft-tissue infection. Empirical use of agents active against community-acquired MRSA is warranted for patients presenting with serious skin and soft-tissue infections.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app