We have located links that may give you full text access.
Characterisation of metal-chelate methacrylate monoliths.
Journal of Chromatography. A 2006 March 18
Monoliths are attractive stationary phases for purification of large biomolecules like proteins because of their flow-unaffected properties. Isolation of histidine containing proteins to high purity can be efficiently performed using metal-chelate interactions within a single chromatographic step. In this work, we investigated properties of commercial metal-chelate methacrylate monoliths-Convective Interaction Media (CIM). Analytical CIM disk monolithic columns and CIM 8 ml monolithic columns were used for purification of tumor necrosis factor-alpha (TNF-alpha) analog LK-801 and green fluorescence protein with 6 histidine tag (GFP-6His). In both cases, purity over 90% was achieved. Dynamic binding capacity at 10% of breakthrough was around 17-18 mg/ml for LK-801 and around 30 mg/ml for GFP-6His. Adsorption isotherm revealed that the maximal capacity is achieved at protein concentration above 60 microg/ml. Dynamic binding capacity and resolution were found to be flow unaffected.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app