We have located links that may give you full text access.
The anion gap does not accurately screen for lactic acidosis in emergency department patients.
Emergency Medicine Journal : EMJ 2006 March
INTRODUCTION: Lactic acidosis portends a poor prognosis in trauma, sepsis, and other shock states and is useful for triaging and resuscitating emergency department (ED) patients. The authors sought to determine whether the AG is a reliable screen for lactic acidosis when applied specifically in the ED setting.
METHODS: The authors performed a retrospective cohort study over a seven month period. Subjects were all ED patients that had a serum lactate obtained. Sensitivity analyses of the AG for detecting presence of lactic acidosis were calculated for the traditional AG normal value (AG <12) and for the lower AG normal value when using newer ion selective electrode assays (AG <6).
RESULTS: Serum lactate levels were ordered in the ED on 440 occasions. 137 samples were excluded by protocol. Using an AG cutoff of 12, the sensitivity for detecting lactic acidosis was 58.2%, specificity was 81.0%, and the negative predictive value was 89.7%. Using the AG cutoff of 6, the sensitivity was 93.2%, the specificity was 17.3%, and the negative predictive value was 91.8%.
CONCLUSIONS: The traditional definition of AG >12 was insensitive for the presence of lactic acidosis. Using the revised AG of >6 is more sensitive but non-specific for lactic acidosis. The authors conclude that employing the AG as a screen for LA may be inappropriate in ED patients. Instead, they recommend ordering a serum lactate immediately upon suspicion of a shock state. A prospective study to confirm these findings is needed.
METHODS: The authors performed a retrospective cohort study over a seven month period. Subjects were all ED patients that had a serum lactate obtained. Sensitivity analyses of the AG for detecting presence of lactic acidosis were calculated for the traditional AG normal value (AG <12) and for the lower AG normal value when using newer ion selective electrode assays (AG <6).
RESULTS: Serum lactate levels were ordered in the ED on 440 occasions. 137 samples were excluded by protocol. Using an AG cutoff of 12, the sensitivity for detecting lactic acidosis was 58.2%, specificity was 81.0%, and the negative predictive value was 89.7%. Using the AG cutoff of 6, the sensitivity was 93.2%, the specificity was 17.3%, and the negative predictive value was 91.8%.
CONCLUSIONS: The traditional definition of AG >12 was insensitive for the presence of lactic acidosis. Using the revised AG of >6 is more sensitive but non-specific for lactic acidosis. The authors conclude that employing the AG as a screen for LA may be inappropriate in ED patients. Instead, they recommend ordering a serum lactate immediately upon suspicion of a shock state. A prospective study to confirm these findings is needed.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app