Clinical Trial
Journal Article
Add like
Add dislike
Add to saved papers

Do stroke patients with normal carotid arteries require TEE for exclusion of relevant aortic plaques?

OBJECTIVES: This study investigated (a) the hypothesis that stroke patients with aortic atheroma would show comparable atherosclerotic changes in the carotid arteries, which are easily accessible for ultrasound evaluation and (b) the possibility of carotid duplex sonography as a replacement for transoesophageal echocardiography (TEE) for the exclusion or prediction of relevant aortic plaques.

METHODS: In 301 consecutive patients (mean age 62 years) with acute cerebral ischaemia, two dimensional ultrasound measurements were taken of common carotid artery intima media thickness (IMT) and maximal plaque area (PA) and the local degree of internal carotid artery (ICA) stenosis were determined. Maximal aortic wall thickness (AWT) was assessed by TEE.

RESULTS: An IMT < or =0.9 mm yielded a negative predictive value (NPV) of 95.8% for exclusion of aortic atheromas > or =4 mm and an NPV of 100% for the exclusion of aortic thrombi. However, positive predictive value of IMT >0.9 mm was low (29.6%), increasing only slightly in the presence of carotid plaques (33%). Incidence of aortic thrombi was significantly higher with > or =50% compared with <50% ICA stenosis (11.3% v 3.9%, respectively). IMT and PA correlated moderately with AWT (r = 0.47, r = 0.53, respectively; p<0.001). Systolic blood pressure, coronary heart disease and peripheral artery disease, increased IMT, and ICA stenosis > or =50% were independently related to AWT > or =4 mm.

CONCLUSIONS: A high NPV of normal carotid ultrasound does not support routine TEE for the exclusion of complex aortic plaques as a high risk source of cerebral embolism. However, in patients with carotid atherosclerosis, particularly in those with ICA stenosis > or =50%, TEE should be performed to exclude an additional high risk source for stroke.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app