COMPARATIVE STUDY
JOURNAL ARTICLE
RESEARCH SUPPORT, N.I.H., EXTRAMURAL
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Normal tissue complication probability modeling for acute esophagitis in patients treated with conformal radiation therapy for non-small cell lung cancer.

PURPOSE: To evaluate the ability of a well-known normal tissue complication probability (NTCP) model to predict radiation esophagitis by determining updated model parameters and then comparing these results with the predictive value of other dosimetric parameters.

MATERIAL AND METHODS: Clinical and dosimetric data regarding esophagitis were analyzed in 101 inoperable/unresectable non-small-cell lung cancer patients treated by external beam irradiation. Grade 2 or higher esophagitis counted as events. Parameters (TD50, n, and m) of the Lyman normal tissue complication probability (NTCP) model were determined using maximum likelihood analysis, and compared to other dose/volume threshold values including: percentage of esophagus receiving > 40 Gy (V40) to > 75 Gy (V75), and maximum esophageal doses.

RESULTS: Sixteen patients developed grade 2-3 acute esophagitis (no G4 or 5). The maximum likelihood analysis produced new Lyman model parameters of: TD50 = 51 Gy, n = 0.44 and m = 0.32. The mean NTCP value is significantly lower (P < 0.001) in the group of patients without esophagitis (13.5%) than with esophagitis (27.2%). The rates of esophagitis are 2.5, 7, 9 and 13.4%, respectively, when the NTCP values are <10%, <15%, <20% and <25%. A significant association is found between esophagitis and dose/volume parameters V40 (P = 0.001) to V70 (P = 0.024).

CONCLUSIONS: New values of TD50, n and m offer a good description of the esophagitis distribution in our population. Compared to the use of this model with previously published parameters (associated with late toxicity) predictions of the model for acute esophagitis using the new parameters would indicate that, for a population of patients, the distribution of events as a function of uniform dose would occur with a lower mean uniform dose value (smaller TD50), over a wider range of uniform doses (larger m), while also exhibiting a bigger volume effect (larger n). These new parameter values are supported in essence by the correlations found for the dose/volume threshold parameters.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app