JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Respiratory dead space measurement in the investigation of pulmonary embolism in outpatients with pleuritic chest pain.

Chest 2005 October
STUDY OBJECTIVES: Pleuritic chest pain is a common presenting condition in the emergency department. A noninvasive bedside rule out test for pulmonary embolism would aid investigating this patient group. Our study aimed to compare the clinical utility of three methods for calculating respiratory dead space in the diagnosis of pulmonary embolism in outpatients with pleuritic chest pain.

DESIGN: Prospective diagnostic study.

SETTING: Large city-center emergency department.

PATIENTS: Between February 2002 and June 2003, 425 patients presenting to the emergency department with pleuritic chest pain were prospectively recruited.

INTERVENTION: Data collection for respiratory dead space was performed in the emergency department by two researchers. The respiratory dead space fraction was calculated independently using three different methods. All patients underwent an independent reference standard diagnostic algorithm to establish the presence or absence of pulmonary embolism. Those with a low modified Wells clinical probability and a normal quantitative d-dimer finding were discharged home. All others followed a reference standard protocol using Prospective Investigation of Pulmonary Embolism Diagnosis-interpreted ventilation/perfusion scanning, CT pulmonary angiography, and digital subtraction pulmonary angiography. All patients were followed up clinically for 3 months.

MEASUREMENTS AND RESULTS: For the Bohr calculation, the area under the receiver operating characteristic curve was 0.62 (95% confidence interval [CI], 0.51 to 0.73), the Enghoff calculation was 0.66 (95% CI, 0.55 to 0.77), and the capillary sample Enghoff was 0.62 (95% CI, 0.49 to 0.65). The optimum Bohr cutoff value gave 100.0% sensitivity (95% CI, 84.5 to 100%) but a low specificity of 22.7% (95% CI, 18.8 to 27.2%). The optimum cutoff points for Enghoff and capillary Enghoff calculations gave sensitivities of 95.3% (95% CI, 77.3 to 99.2%) and 94.4% (95% CI, 74.2 to 99.0%), respectively, with poor specificity.

CONCLUSIONS: Respiratory dead space analysis does not perform well as a stand-alone diagnostic test for pulmonary embolism in outpatients presenting with pleuritic chest pain.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app