COMPARATIVE STUDY
JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

An optimisation algorithm for determination of treatment margins around moving and deformable targets.

PURPOSE: Determining treatment margins for inter-fractional motion of moving and deformable clinical target volumes (CTVs) remains a major challenge. This paper describes and applies an optimisation algorithm designed to derive such margins.

MATERIAL AND METHODS: The algorithm works by expanding the CTV, as determined from a pre-treatment or planning scan, to enclose the CTV positions observed during treatment. CTV positions during treatment may be obtained using, for example, repeat CT scanning and/or repeat electronic portal imaging (EPI). The algorithm can be applied to both individual patients and to a set of patients. The margins derived will minimise the excess volume outside the envelope that encloses all observed CTV positions (the CTV envelope). Initially, margins are set such that the envelope is more than adequately covered when the planning CTV is expanded. The algorithm uses an iterative method where the margins are sampled randomly and are then either increased or decreased randomly. The algorithm is tested on a set of 19 bladder cancer patients that underwent weekly repeat CT scanning and EPI throughout their treatment course.

RESULTS: From repeated runs on individual patients, the algorithm produces margins within a range of +/-2 mm that lie among the best results found with an exhaustive search approach, and that agree within 3mm with margins determined by a manual approach on the same data. The algorithm could be used to determine margins to cover any specified geometrical uncertainty, and allows for the determination of reduced margins by relaxing the coverage criteria, for example disregarding extreme CTV positions, or an arbitrarily selected volume fraction of the CTV envelope, and/or patients with extreme geometrical uncertainties.

CONCLUSION: An optimisation approach to margin determination is found to give reproducible results within the accuracy required. The major advantage with this algorithm is that it is completely empirical, and it is therefore particularly useful for CTVs where the geometrical uncertainties are difficult to model, such as the bladder.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app