COMPARATIVE STUDY
EVALUATION STUDIES
JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

In vivo assessment of trabecular bone microarchitecture by high-resolution peripheral quantitative computed tomography.

CONTEXT: Assessment of trabecular microarchitecture may enhance the prediction of fracture risk and improve monitoring of treatment response. A new high-resolution peripheral quantitative computed tomography (HR-pQCT) system permits in vivo assessment of trabecular architecture and volumetric bone mineral density (BMD) at the distal radius and tibia with a voxel size of 82 microm3.

OBJECTIVE AND PATIENTS: We determined the short-term reproducibility of this device by measuring 15 healthy volunteers three times each. We compared HR-pQCT measurements in 108 healthy premenopausal, 113 postmenopausal osteopenic, and 35 postmenopausal osteoporotic women. Furthermore, we compared values in postmenopausal osteopenic women with (n = 35) and without previous fracture history (n = 78).

DESIGN AND SETTING: We conducted a cross-sectional study in a private clinical research center.

INTERVENTION AND MAIN OUTCOME MEASURE: We took HR-pQCT measurements of the radius and tibia. Femoral neck and spine BMD were measured in postmenopausal women by dual-energy x-ray absorptiometry.

RESULTS: Precision of HR-pQCT measurements was 0.7-1.5% for total, trabecular, and cortical densities and 2.5-4.4% for trabecular architecture. Postmenopausal women had lower density, trabecular number, and cortical thickness than premenopausal women (P < 0.001) at both radius and tibia. Osteoporotic women had lower density, cortical thickness, and increased trabecular separation than osteopenic women (P < 0.01) at both sites. Furthermore, although spine and hip BMD were similar, fractured osteopenic women had lower trabecular density and more heterogeneous trabecular distribution (P < 0.02) at the radius compared with unfractured osteopenic women.

CONCLUSION: HR-pQCT appears promising to assess bone density and microarchitecture at peripheral sites in terms of reproducibility and ability to detect age- and disease-related changes.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app