We have located links that may give you full text access.
COMPARATIVE STUDY
JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Physiologic assessment of jailed side branch lesions using fractional flow reserve.
Journal of the American College of Cardiology 2005 August 17
OBJECTIVES: This study was performed to evaluate the feasibility of the physiologic assessment of jailed side branches using fractional flow reserve (FFR) and to compare the measured FFR with the stenosis severity assessed by quantitative coronary angiography (QCA).
BACKGROUND: It is not well-known which side branches should be treated after stent implantation at main branches and how to assess the functional significance of these lesions.
METHODS: Ninety-seven jailed side branch lesions (vessel size > 2.0 mm, percent stenosis > 50% by visual estimation) after stent implantation at main branches were consecutively enrolled. The FFR was measured using a pressure wire at 5 mm distal and proximal to the ostial lesion of the jailed side branch.
RESULTS: The FFR measurement was successful in 94 lesions. Mean FFRs were 0.94 +/- 0.04 and 0.85 +/- 0.11 at the main branches and jailed side branches, respectively. There was a negative correlation between the percent stenosis and FFR (r = -0.41, p < 0.001). However, no lesion with < 75% stenosis had FFR < 0.75. Among 73 lesions with > or = 75% stenosis, only 20 lesions were functionally significant.
CONCLUSIONS: The FFR measurement in jailed side branch lesions is both safe and feasible. Quantitative coronary angiography is unreliable in the assessment of the functional severity of jailed side branch lesions, and measurement of FFR suggests that most of these lesions do not have functional significance.
BACKGROUND: It is not well-known which side branches should be treated after stent implantation at main branches and how to assess the functional significance of these lesions.
METHODS: Ninety-seven jailed side branch lesions (vessel size > 2.0 mm, percent stenosis > 50% by visual estimation) after stent implantation at main branches were consecutively enrolled. The FFR was measured using a pressure wire at 5 mm distal and proximal to the ostial lesion of the jailed side branch.
RESULTS: The FFR measurement was successful in 94 lesions. Mean FFRs were 0.94 +/- 0.04 and 0.85 +/- 0.11 at the main branches and jailed side branches, respectively. There was a negative correlation between the percent stenosis and FFR (r = -0.41, p < 0.001). However, no lesion with < 75% stenosis had FFR < 0.75. Among 73 lesions with > or = 75% stenosis, only 20 lesions were functionally significant.
CONCLUSIONS: The FFR measurement in jailed side branch lesions is both safe and feasible. Quantitative coronary angiography is unreliable in the assessment of the functional severity of jailed side branch lesions, and measurement of FFR suggests that most of these lesions do not have functional significance.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app