MENU ▼
Read by QxMD icon Read
search
OPEN IN READ APP
JOURNAL ARTICLE

Quantitative assessment of pleural effusion in critically ill patients by means of ultrasonography

Philippe Vignon, Catherine Chastagner, Vanessa Berkane, Eric Chardac, Bruno François, Sandrine Normand, Michel Bonnivard, Marc Clavel, Nicolas Pichon, Pierre-Marie Preux, Antoine Maubon, Hervé Gastinne
Critical Care Medicine 2005, 33 (8): 1757-63
16096453

OBJECTIVE: To assess the ability of ultrasonography to identify the presence and assess the volume of pleural effusion in the intensive care unit setting.

DESIGN: Prospective descriptive clinical study.

SETTING: Medical-surgical intensive care unit of a teaching hospital.

PATIENTS: Initial study group (group I) consisted of 97 patients (mean [+/-SD] Simplified Acute Physiology Score II, 40 +/- 14) with clinically suspected pleural effusion. Fifty-one patients were mechanically ventilated and 55 patients underwent a unilateral or bilateral thoracentesis (58 procedures). All patients underwent supine chest radiography and pleural ultrasonography at bedside. The testing group (group II) consisted of 19 additional patients (17 under ventilation) who underwent thoracentesis.

INTERVENTIONS: None.

MEASUREMENTS AND MAIN RESULTS: Maximal interpleural distance was measured at the base and apex of the pleural space, at both end-expiration and end-inspiration. In group I, interpleural distances were compared to actual volume of fluid in the subset of patients who underwent a complete thoracentesis (n = 49). Prediction of the volume of pleural effusion was subsequently tested prospectively in group II (25 complete thoracenteses). Portable chest radiography and pleural ultrasonography yielded discordant results for 47 patients (48%) in the diagnosis of pleural effusion. The expiratory interpleural distance measured at the thoracic base with ultrasonography was significantly correlated with the volume of fluid (p < .0001; coefficient of determination: right, 0.78; left, 0.51). A pleural effusion > or =800 mL was predicted when this distance was >45 mm (right) or >50 mm (left), with a sensitivity of 94% and 100% and a specificity of 76% and 67%, respectively. In group II, the mean bias between the predicted and observed volumes of pleural effusion determined by thoracentesis was 24 +/- 355 mL, and this decreased to 28 +/- 146 mL for the prediction of pleural effusion <1400 mL.

CONCLUSIONS: Bedside ultrasonography is well suited for the quantitative assessment of unloculated pleural effusions in intensive care unit patients.

Comments

You need to log in or sign up for an account to be able to comment.

No comments yet, be the first to post one!

Related Papers

Available on the App Store

Available on the Play Store
Remove bar
Read by QxMD icon Read
16096453
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"